Country Code: UA Language Code: UA Account Type: Google Any Further Comments: Initially validated through Google account. The LG ThinQ app for android has been working great for several years...
Hi guys. I also bought this device. I also received an unsupported device. Logger: homeassistant.components.xiaomi_miio Source: components/xiaomi_miio/__init__.py:130 Integration: Xiaomi Miio (documentation, issues) First occurred: 4 червня 2023 р. о 22:34:49...
I already have 4 such devices. Now I use HACS. But we really need direct support from HA!
i ignored version 1.35.2 and upgraded from 1.35.1-1 to 135.2-1. I don't have a backup from 1.35.2 to check. i installed [1.35.2](https://github.com/Koenkk/zigbee2mqtt/releases/tag/1.35.2) on a separate server.  i received the...
this is a record of a working outlet from the version 1.35.1-1 database: "id":3,"type":"Router","ieeeAddr":"0xa4c138fb9c8d1217","nwkAddr":58137,"manufId":4417,"manufName":"_TZ3000_o1jzcxou","powerSource":"Mains (single phase)","modelId":"TS011F","epList":[1,242],"endpoints":{"1":{"profId":260,"epId":1,"devId":266,"inClusterList":[3,4,5,6,57344,57345,0],"outClusterList":[25,10],"clusters":{"genBasic":{"attributes":{"modelId":"TS011F","manufacturerName":"_TZ3000_o1jzcxou","powerSource":1,"zclVersion":3,"appVersion":64,"stackVersion":0,"hwVersion":1,"dateCode":""}},"genOnOff":{"attributes":{"32768":0,"onOff":0,"onTime":0,"offWaitTime":0,"tuyaBacklightMode":1,"moesStartUpOnOff":2,"tuyaBacklightSwitch":1}},"manuSpecificTuya_3":{"attributes":{"powerOnBehavior":2,"switchType":0}}},"binds":[],"configuredReportings":[],"meta":{}},"242":{"profId":41440,"epId":242,"devId":97,"inClusterList":[],"outClusterList":[33],"clusters":{},"binds":[],"configuredReportings":[],"meta":{}}},"appVersion":64,"stackVersion":0,"hwVersion":1,"dateCode":"","zclVersion":3,"interviewCompleted":true,"meta":{},"lastSeen":1707043545757,"defaultSendRequestWhen":"immediate" I see that 2 different devices have the same registration details. so the problem...
Friend, @martinw72 what problem do you have? 1. Does your outlet with energy monitoring look like a regular outlet? 2. Does your outlet without energy monitoring look like an outlet...
The problem is that the manufacturer made 2 different devices (with energy monitoring and without energy monitoring) with the same ID _TZ3000_o1jzcxou. To solve this problem, you need to manually...
If your version of Z2M is greater than 2.0, it is not installed in the directory with HA. Go to the Z2M location folder and create a folder named external_converters...
@andrei-lazarov Yes. After almost a year, I'm not sure anymore. Maybe you're right: the problem is not with the manufacturer, but with the converter. In one converter, two fingerprints from...