Looks like it does not support the upgraded version of 86 Single Wireless Switch.

I took a look at the related code for single wireless switch, actually the code for upgraded version (double press) are already there. If you are able / willing to...

我也遇到了这个问题,虽然这个解决方法比较暴力,但经测试可以防止 HB 崩溃,红外信号也能发出去。去 `config/node_modules/homebridge-mi-acpartner/accessories/baseSwitch.js` 把 83 行的 `callback(err);` 注释掉就好了。 稍后有空再看看究竟是啥问题…

> 有没有可能是因为发送间隔太短的缘故,可以帮忙测试下延长发送时间BUG能否解决呢? 调整 `sendInterval` 到 1000 后仍然报错,貌似不是发送间隔的问题… --- 硬件:小米空调伴侣(圆形) 配置: `{ "name": "Bedroom Lightbulb", "type": "switchRepeat", "sendInterval": 1000, "data": { "on": [ "FEXXXXXXX", "FEXXXXXXX" ], "off": [ "FEXXXXXXX", "FEXXXXXXX" ]...

> 试了你的方法,HB依然会崩溃…… 试试重启 HB 或者整个容器?我这边只要不返回错误 HB 就不会崩溃,就是每一个红外代码发送会有一条错误日志: `[XiaoMiAcPartner] [Master Bedroom Lightbulb]Failed! TypeError: callback is not a function`