hassio-zigbee2mqtt
hassio-zigbee2mqtt copied to clipboard
After update 1.35.2 to 1.35.3 ZigBee2MQTT Started and next 30 second Stopped
Description of the issue
After update 1.35.2 to 1.35.3 ZigBee2MQTT Started and next 15-30 second Stopped :(((
In Log:
/app/node_modules/winston-transport/node_modules/readable-stream/lib/_stream_writable.js:264 var er = new ERR_STREAM_WRITE_AFTER_END(); ^ Error: write after end at writeAfterEnd (/app/node_modules/winston-transport/node_modules/readable-stream/lib/_stream_writable.js:264:12) at File.Writable.write (/app/node_modules/winston-transport/node_modules/readable-stream/lib/_stream_writable.js:300:21) at DerivedLogger.ondata (/app/node_modules/winston/node_modules/readable-stream/lib/_stream_readable.js:629:20) at DerivedLogger.emit (node:events:517:28) at DerivedLogger.Readable.read (/app/node_modules/winston/node_modules/readable-stream/lib/_stream_readable.js:451:26) at flow (/app/node_modules/winston/node_modules/readable-stream/lib/_stream_readable.js:858:34) at File.pipeOnDrainFunctionResult (/app/node_modules/winston/node_modules/readable-stream/lib/_stream_readable.js:690:7) at File.emit (node:events:517:28) at onwriteDrain (/app/node_modules/winston-transport/node_modules/readable-stream/lib/_stream_writable.js:453:12) at afterWrite (/app/node_modules/winston-transport/node_modules/readable-stream/lib/_stream_writable.js:441:18)
How to downgrade or fix a this error?
Addon version
1.35.3
Platform
Home Assistant 2024.1.6 Supervisor 2024.01.1 Debian 12 OS Agent 1.6.0 Docker 25.0.3 Coordinator firmware version: 6.6.5.0 build 204, type: EZSP v7
Logs of the issue (if applicable)
No response
remove and insert the USB coordinator, it helped me
remove and insert the USB coordinator, it helped me
I tried it, completely disconnected the power, turned it on, the error did not go away.
How to go back to 1.35.2? I don't understand what the problem is with the new version.
+1 The same here . How to go back to 1.35.2? Zigbee2MQTT-Version 1.35.3 commit: unknown Coordinator-Typ zStack3x0 Coordinator-Version 20230507 Coordinator IEEE Adresse 0x00124b002c3a6401 Frontend-Version 0.6.156 zigbee_herdsman_converters_version 18.28.3 zigbee_herdsman_version 0.33.8 Statistiken Gesamt 58 Nach Typ Router: 33 Endgerät: 25
I have the same problem in version 135.2-1 and also in 135.3-1 Coordinator-Typ: Skyconnect EZSP v12 Coordinator-Version 7.3.2.0 build 212 Router: 63 Endgerät: 30
I tried to solve the problem by switching back to version 1.35.2-1 (backup of Home Assistant), but without success.
Only 135.1-1 works for me, all subsequent versions have the problem. The 135.1-1 runs without any problems.
Same problem here with 1.35.3-1 but I don't have much details in /config/logs:
[17:59:29] INFO: Preparing to start...
[17:59:31] INFO: Socat not enabled
[17:59:37] INFO: Starting Zigbee2MQTT...
@asan84 can you provide me your z2m configuration.yaml?
@asan84 can you provide me your z2m configuration.yaml?
Hello Koenkk, here is my configuration.yaml. X = Secret :-)
homeassistant: true advanced: channel: 15 network_key: - 207 - 0 - XXXXXX - 96 - 29 - 55 - XXXXXX - 33 - 4 - XXXXXX - 26 - 54 - 85 - 60 - 15 - 67 pan_id: 42440 ext_pan_id: - 247 - XXXXX - 82 - XXXXX - 40 - 32 - XXXXXX - XXXXXX homeassistant_legacy_entity_attributes: false legacy_api: false legacy_availability_payload: false log_level: info log_syslog: app_name: Zigbee2MQTT eol: /n host: localhost localhost: localhost path: /dev/log pid: process.pid port: 514 protocol: udp4 type: '5424' last_seen: ISO_8601_local mqtt: server: mqtt://core-mosquitto:1883 user: addons password: XXXXXXXX port: /dev/ttyUSB0 frontend: port: 8099 device_options: legacy: false devices: '0x00158d0008d0b120': friendly_name: WM Pufferspeicher | Heizraum '0xc4988600000cac5e': friendly_name: WC Licht 1 '0x0ceff6fffedfd53e': friendly_name: HKT WC '0x0017880106f90047': friendly_name: HUE Schrank Wohnzimmer '0x001788010331074e': friendly_name: HUE Uhr Wohnzimmer '0x0017880103316314': friendly_name: HUE Ecke Couch Wohnzimmer '0x001788010330ad16': friendly_name: HUE Terrassentür Wohnzimmer '0x0017880106fd5a92': friendly_name: HUE TV Rechts Wohnzimmer '0x0017880106fd59b2': friendly_name: HUE TV Links Wohnzimmer '0x001788010406f022': friendly_name: HUE Strip Bad '0xb0c7defffeeb39cd': friendly_name: HKT Schlafzimmer '0x3410f4fffeb2a850': friendly_name: HKT Schlafzimmer 2 '0x0ceff6fffeb95b4f': friendly_name: HKT Flur OG '0x0ceff6fffedc7876': friendly_name: HKT Bad OG '0x0ceff6fffedd9439': friendly_name: HKT Büro '0x0ceff6fffedc9fbe': friendly_name: HKT Küche '0x000d6f0014f7de56': friendly_name: CO Sensor Wohnzimmer '0x001788010bcff5d8': friendly_name: BM Schlafzimmer 2 '0x001788010bcfe674': friendly_name: BM Philips HUE '0x00158d0008d095ee': friendly_name: WM Waschmaschine Trockner | Eingang UG '0x00158d0008dffb06': friendly_name: WM Hauptwasseranschluss | Abstellraum '0x0ceff6fffeb95b07': friendly_name: HKT Flur UG '0x0ceff6fffedcbe0f': friendly_name: HKT Fitnessraum '0x0ceff6fffedfd47f': friendly_name: HKT Bad UG '0x0ceff6fffedca2a3': friendly_name: HKT Gästezimmer '0x000d6f001491b1cb': friendly_name: CO Sensor Heizraum '0x001788010d3572f7': friendly_name: FB Philips HUE Dial 1 Büro '0x804b50fffee0df75': friendly_name: R2 L1 Licht Lounge '0x804b50fffee2917f': friendly_name: R4 L5 Licht Lounge '0x804b50fffee273d1': friendly_name: R2 L3 Licht Lounge '0x804b50fffee27ace': friendly_name: R1 L2 Licht Lounge '0x804b50fffee0e01f': friendly_name: R2 L2 Licht Lounge '0xcc86ecfffe1c6095': friendly_name: R1 L5 Licht Lounge '0x804b50fffee273c5': friendly_name: R4 L6 Licht Lounge '0x804b50fffee27360': friendly_name: R1 L6 Licht Lounge '0x804b50fffee0e5b6': friendly_name: R1 L3 Licht Lounge '0x804b50fffee0e6d0': friendly_name: R1 L1 Licht Lounge '0xcc86ecfffe1d7732': friendly_name: R4 L1 Licht Lounge '0xc498860000da354c': friendly_name: ACDC Lampe Licht Lounge '0x804b50fffee0e28e': friendly_name: R4 L3 Licht Lounge '0x804b50fffee2781d': friendly_name: R1 L4 Licht Lounge '0x00178801097a2680': friendly_name: R3 L1 Licht Lounge '0x0017880109719b3a': friendly_name: R3 L3 Licht Lounge '0x00178801096fdc51': friendly_name: R3 L2 Licht Lounge '0x804b50fffee274e6': friendly_name: R2 L4 Licht Lounge '0x001788010b80e724': friendly_name: HUE Leselicht Lounge '0x00178801033251c4': friendly_name: HUE Iris Lounge '0x00124b002342e139': friendly_name: BM Treppenhaus EG '0x00124b0023adff17': friendly_name: BM Treppenhaus DG '0xcc86ecfffedb35e4': friendly_name: Licht Treppenhaus OG-DG '0x0017880102d54bab': friendly_name: FB Philips HUE 1 WC legacy: true '0x001788010406bbbd': friendly_name: HUE Strip Büro '0x804b50fffee0e6f2': friendly_name: R4 L2 Licht Lounge '0x84fd27fffe698237': friendly_name: R4 L4 Licht Lounge '0x00178801096fc16a': friendly_name: R3 L4 Licht Lounge '0x001788010dd00b6f': friendly_name: FB Philips HUE Dial 2 Lounge '0x001788010d8bb2dc': friendly_name: FB Philips HUE 2 ota: ikea_ota_use_test_url: false zigbee_ota_override_index_location: https://raw.githubusercontent.com/Koenkk/zigbee-OTA/master/index.json
I have two Sonoff Dongles:
- Version P for Zigbee on Chanel 15
- Version E for Thread on Chanel 25 (FIrmware is Flash only for Thread, not vor Multiprotocol)
Zigbee2MQTT-Version 1.35.2 commit: unknown Coordinator-Typ zStack3x0 Coordinator-Version 20230507 Coordinator IEEE Adresse 0x00124b002c3a6401 Frontend-Version 0.6.152 Zigbee-herdsman-converters version 18.25.1 Zigbee-herdsman version 0.33.5
I think it's because of the log_syslog, can you remove it from your configuration.yaml and see if that fixes the problem?
I think it's because of the
log_syslog, can you remove it from yourconfiguration.yamland see if that fixes the prob
Hi Koenkk, thanks for the feedback. Unfortunately no change in behavior. The adapter restarts every 3-4 minutes for me. I am back to version 1.35.1, no problems there, the adapter runs stable.
the same issue Current version: 1.35.3-1 ZB-GW04 USB
I think it's because of the
log_syslog, can you remove it from yourconfiguration.yamland see if that fixes the problem?
I didn't turn off the log_syslog. The service started automatically after stopping on the 10th attempt.
It has loaded and hasn't stopped yet.
I don't understand what the problem is with the new version.
@asan84 can you SSH into your system, execute the following and see if the issue is fixed?
docker exec -it $(docker ps | grep zigbee2mqtt | cut -d" " -f 1) /bin/sh
apk add npm
npm install [email protected]
exit
docker restart $(docker ps | grep zigbee2mqtt | cut -d" " -f 1)
Make sure to not restart the addon via the HA interface, these changes will get lost.
@asan84 can you SSH into your system, execute the following and see if the issue is fixed?
docker exec -it $(docker ps | grep zigbee2mqtt | cut -d" " -f 1) /bin/sh apk add npm npm install [email protected] exit docker restart $(docker ps | grep zigbee2mqtt | cut -d" " -f 1)Make sure to not restart the addon via the HA interface, these changes will get lost.
It did not work, now the process is rebooting again.
The last time it gave an error and stopped: [22:38:47] INFO: Preparing to start... [22:38:52] INFO: Socat not enabled [22:39:09] INFO: Starting Zigbee2MQTT... Zigbee2MQTT:error 2024-02-18 22:40:10: Failed to read state of '0x588e81fffeb07c8a' after reconnect (Read 0x588e81fffeb07c8a/1 genOnOff(["onOff"], {"timeout":10000,"disableResponse":false, "disableRecovery":false,"disableDefaultResponse":true,"direction":0,"srcEndpoint":null,"reservedBits":0,"manufacturerCode":null,"transactionSequenceNumber":null,"writeUndiv":false}) failed (sendZclFrameToEndpointInternal error))
The process started stably after 5 minutes, after several falls.
But, process stopped again:
[22:41:52] INFO: Preparing to start... [22:41:57] INFO: Socat not enabled [22:42:14] INFO: Starting Zigbee2MQTT... Zigbee2MQTT:error 2024-02-18 22:48:19: Failed to configure '0x54ef44100087d7f0', attempt 1 (Error: Read 0x54ef44100087d7f0/1 genPowerCfg(["batteryVoltage"], {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":true,"direction":0,"srcEndpoint":null,"reservedBits":0,"manufacturerCode":null,"transactionSequenceNumber":null,"writeUndiv":false}) failed (Timeout - 30829 - 1 - 12 - 1 - 1 after 10000ms) at Object.start (/app/node_modules/zigbee-herdsman/src/utils/waitress.ts:63:23) at EZSPAdapter.sendZclFrameToEndpointInternal (/app/node_modules/zigbee-herdsman/src/adapter/ezsp/adapter/ezspAdapter.ts:486:47) at Queue.execute (/app/node_modules/zigbee-herdsman/src/utils/queue.ts:35:20) at Request.send (/app/node_modules/zigbee-herdsman/src/controller/helpers/request.ts:79:20) at Endpoint.read (/app/node_modules/zigbee-herdsman/src/controller/model/endpoint.ts:466:28) at configure (/app/node_modules/zigbee-herdsman-converters/src/devices/lumi.ts:1778:13) at Object.configure (/app/node_modules/zigbee-herdsman-converters/src/index.ts:141:25) at Configure.configure (/app/lib/extension/configure.ts:120:13) at EventEmitter.wrappedCallback (/app/lib/eventBus.ts:174:17)) Zigbee2MQTT:info 2024-02-18 22:52:23: Successfully changed options Zigbee2MQTT:info 2024-02-18 22:52:23: MQTT publish: topic 'zigbee2mqtt/bridge/response/options', payload '{"data":{"restart_required":false},"status":"ok","transaction":"tjlq7-1"}' Zigbee2MQTT:debug 2024-02-18 22:52:30: Received MQTT message on 'zigbee2mqtt/bridge/request/permit_join' with data '{"device":null,"time":254,"transaction":"tjlq7-2","value":true}' Zigbee2MQTT:info 2024-02-18 22:52:31: Zigbee: allowing new devices to join. Zigbee2MQTT:debug 2024-02-18 22:52:31: Received Zigbee message from 'Coordinator', type 'commandNotification', cluster 'greenPower', data '{"data":[25,15,2,11,254,0],"type":"Buffer"}' from endpoint 242 with groupID null, ignoring since it is from coordinator Zigbee2MQTT:info 2024-02-18 22:52:31: MQTT publish: topic 'zigbee2mqtt/bridge/response/permit_join', payload '{"data":{"time":254,"value":true},"status":"ok","transaction":"tjlq7-2"}' Zigbee2MQTT:debug 2024-02-18 22:52:31: Received Zigbee message from '0x54ef4410009a4274', type 'read', cluster 'genTime', data '["timeZone","time"]' from endpoint 1 with groupID 0 Zigbee2MQTT:debug 2024-02-18 22:52:43: Received Zigbee message from '0x00124b002236e95a', type 'attributeReport', cluster 'genOnOff', data '{"onOff":0}' from endpoint 1 with groupID 0 Zigbee2MQTT:info 2024-02-18 22:52:43: MQTT publish: topic 'zigbee2mqtt/0x00124b002236e95a', payload '{"device":{"applicationVersion":2,"dateCode":"20191113","friendlyName":"0x00124b002236e95a","hardwareVersion":1,"ieeeAddr":"0x00124b002236e95a","manufacturerID":0,"manufacturerName":"SONOFF","model":"BASICZBR3","networkAddress":22084,"powerSource":"Mains (single phase)","type":"Router","zclVersion":1},"linkquality":88,"state":"OFF"}' Zigbee2MQTT:debug 2024-02-18 22:52:53: Saving state to file /config/zigbee2mqtt/state.json Zigbee2MQTT:warn 2024-02-18 22:52:56: Device '0x54ef441000848e13' left the network Zigbee2MQTT:info 2024-02-18 22:52:57: MQTT publish: topic 'zigbee2mqtt/bridge/event', payload '{"data":{"friendly_name":"0x54ef441000848e13","ieee_address":"0x54ef441000848e13"},"type":"device_leave"}' Zigbee2MQTT:debug 2024-02-18 22:53:02: Device '0x54ef441000848e13' reconnected Zigbee2MQTT:info 2024-02-18 22:53:02: MQTT publish: topic 'zigbee2mqtt/0x54ef441000848e13/availability', payload '{"state":"online"}' Zigbee2MQTT:info 2024-02-18 22:53:02: Device '0x54ef441000848e13' joined Zigbee2MQTT:info 2024-02-18 22:53:03: MQTT publish: topic 'zigbee2mqtt/bridge/event', payload '{"data":{"friendly_name":"0x54ef441000848e13","ieee_address":"0x54ef441000848e13"},"type":"device_joined"}' Zigbee2MQTT:info 2024-02-18 22:53:03: Starting interview of '0x54ef441000848e13' Zigbee2MQTT:info 2024-02-18 22:53:04: MQTT publish: topic 'zigbee2mqtt/bridge/event', payload '{"data":{"friendly_name":"0x54ef441000848e13","ieee_address":"0x54ef441000848e13","status":"started"},"type":"device_interview"}' Zigbee2MQTT:debug 2024-02-18 22:53:04: Retrieving state of '0x54ef441000848e13' after reconnect Error: Failure send findKeyTableEntry:{"type":"Buffer","data":[135,0,255,0,117,19,142,132,0,16,68,239,84,1]} at /app/node_modules/zigbee-herdsman/src/adapter/ezsp/driver/ezsp.ts:646:23 at Queue.execute (/app/node_modules/zigbee-herdsman/src/utils/queue.ts:35:20) at Driver.cleanupTClinkKey (/app/node_modules/zigbee-herdsman/src/adapter/ezsp/driver/driver.ts:419:24)
Reboot and Stopped again:
Zigbee2MQTT:debug 2024-02-18 23:08:42: Received MQTT message on 'homeassistant/update/0x54ef44100092676b/update/config' with data '{"availability":[{"topic":"zigbee2mqtt/bridge/state","value_template":"{{ value_json.state }}"},{"topic":"zigbee2mqtt/0x54ef44100092676b/availability","value_template":"{{ value_json.state }}"}],"availability_mode":"all","command_topic":"zigbee2mqtt/bridge/request/device/ota_update/update","device":{"identifiers":["zigbee2mqtt_0x54ef44100092676b"],"manufacturer":"Aqara","model":"TVOC air quality monitor (VOCKQJK11LM)","name":"0x54ef44100092676b","sw_version":"2020\u0000www.","via_device":"zigbee2mqtt_bridge_0x0c4314fffe57545e"},"device_class":"firmware","entity_category":"config","entity_picture":"https://github.com/Koenkk/zigbee2mqtt/raw/master/images/logo.png","json_attributes_template":"{"in_progress": {{ iif(value_json['update']['state'] == 'updating', 'true', 'false') }} }","json_attributes_topic":"zigbee2mqtt/0x54ef44100092676b","latest_version_template":"{{ value_json['update']['latest_version'] }}","latest_version_topic":"zigbee2mqtt/0x54ef44100092676b","name":null,"object_id":"0x54ef44100092676b","origin":{"name":"Zigbee2MQTT","sw":"1.35.3","url":"https://www.zigbee2mqtt.io"},"payload_install":"{"id": "0x54ef44100092676b"}","state_topic":"zigbee2mqtt/0x54ef44100092676b","unique_id":"0x54ef44100092676b_update_zigbee2mqtt","value_template":"{{ value_json['update']['installed_version'] }}"}' Zigbee2MQTT:debug 2024-02-18 23:08:42: Active device '0x84fd27fffed1394f' was last seen '0.18' minutes ago.
/app/node_modules/winston-transport/node_modules/readable-stream/lib/_stream_writable.js:264 var er = new ERR_STREAM_WRITE_AFTER_END(); ^ Error: write after end at writeAfterEnd (/app/node_modules/winston-transport/node_modules/readable-stream/lib/_stream_writable.js:264:12) at File.Writable.write (/app/node_modules/winston-transport/node_modules/readable-stream/lib/_stream_writable.js:300:21) at DerivedLogger.ondata (/app/node_modules/winston/node_modules/readable-stream/lib/_stream_readable.js:629:20) at DerivedLogger.emit (node:events:517:28) at DerivedLogger.Readable.read (/app/node_modules/winston/node_modules/readable-stream/lib/_stream_readable.js:451:26) at flow (/app/node_modules/winston/node_modules/readable-stream/lib/_stream_readable.js:858:34) at File.pipeOnDrainFunctionResult (/app/node_modules/winston/node_modules/readable-stream/lib/_stream_readable.js:690:7) at File.emit (node:events:517:28) at onwriteDrain (/app/node_modules/winston-transport/node_modules/readable-stream/lib/_stream_writable.js:453:12) at afterWrite (/app/node_modules/winston-transport/node_modules/readable-stream/lib/_stream_writable.js:441:18)
But it looks like the /app/node_modules/winston-transport/node_modules/readable-stream/lib/_stream_writable.js:264 var er = new ERR_STREAM_WRITE_AFTER_END(); is gone now?
But it looks like the
/app/node_modules/winston-transport/node_modules/readable-stream/lib/_stream_writable.js:264 var er = new ERR_STREAM_WRITE_AFTER_END();is gone now?
No. I've updated the post above.
Reboot and Stopped again: -> this will restart the addon and thus remove the changes, but before the reboot the problem didn't seem to happen?
Maybe.
I can’t repeat it again because the process keeps stopping.
[23:27:49] INFO: Preparing to start... [23:27:53] INFO: Socat not enabled [23:28:11] INFO: Starting Zigbee2MQTT... Zigbee2MQTT:error 2024-02-18 23:29:19: Adapter disconnected, stopping Zigbee2MQTT:error 2024-02-18 23:29:20: Failed to stop Zigbee2MQTT
@asan84 this is probably caused by an issue with the new adapter implementation, soon this will be improved, keep an eye on https://github.com/Koenkk/zigbee-herdsman/pull/918
For the ezsp users, make sure you use the proper configuration for rtscts according to your adapter.
For Skyconnect true, for Sonoff Dongle-E false (if the setting is omitted, then it is false by default).
https://www.zigbee2mqtt.io/guide/configuration/adapter-settings.html
@asan84 from your first post, you are using a very old firmware version. That definitely could cause issues (note that you will have to re-pair everything after update; I wouldn't hope for anything else). https://darkxst.github.io/silabs-firmware-builder/
@Koenkk for the winston stuff, I found several open issues that seem to come and go over the years (in the repo and in packages using winston), but since I don't know winston... :wink:
Hello, I still have the same problem. I use the Skyconnect but if I set the rtscts parameter to "true", even version 135.1-1 no longer starts for me. Zigbee2MQTT version 1.35.1 commit: unknown Coordinator type EZSP v12 Coordinator version 7.3.2.0 build 212
With my current settings, version 135.1-1 runs without any problems.
This error message appears when I set rtscts to true: error 2024-02-19 11:25:01: Error while starting zigbee-herdsman error 2024-02-19 11:25:01: Failed to start zigbee error 2024-02-19 11:25:01: Check https://www.zigbee2mqtt.io/guide/installation/20_zigbee2mqtt-fails-to-start.html for possible solutions error 2024-02-19 11:25:01: Exiting... error 2024-02-19 11:25:02: Error: Failure send version:{"type": "Buffer", "data":[1,0,1,0,0,12]} at /app/node_modules/zigbee-herdsman/src/adapter/ezsp/driver/ezsp.ts:646:23 at Queue.execute (/app/node_modules/zigbee-herdsman/src/utils/queue.ts:35:20) at Ezsp.version (/app/node_modules/zigbee-herdsman/src/adapter/ezsp/driver/ezsp.ts:456:13) at Driver.startup (/app/node_modules/zigbee-herdsman/src/adapter/ezsp/driver/driver.ts:167:9) at Controller.start (/app/node_modules/zigbee-herdsman/src/controller/controller.ts:132:29) at Zigbee.start (/app/lib/zigbee.ts:60:27) at Controller.start (/app/lib/controller.ts:109:27) at start (/app/index.js:107:5)
@Rookman2022 Can you try again with herdsman debug ON and provide the logs? https://www.zigbee2mqtt.io/guide/usage/debug.html#zigbee-herdsman-debug-logging
Also what firmware supplier are you using (Nabu Casa, darkxst, etc)?
I have tested again Version 135.1-1 also runs with "rtscts: true" after the update to 135.3-1 the error appears, see log. I have installed the firmware from Nabu Casa on my SkyConnect V7.3.2.0 build 212
That would seem to indicate your SkyConnect does not like rtscts... strange, but you don't seem to be the only one...
Does it work with 1.35.3-1 if you set rtscts: false (or remove the line entirely, it defaults to false if not provided)?
@kirovilya Do you have a SkyConnect to run some tests on this (I don't)? I'm wondering if serialport is not setting the flags, or if it's getting disabled for some reason (between port opening and NCP reset start)? I though the SkyConnect supported this... (can't seem to find any official info on it though...)
https://serialport.io/docs/api-stream#get
I don't have a skyconnect. I checked on the flashed sticks of ZB-GW04. @Rookman2022 check on the current dev/edge version of z2m - I added a pause there and it should help solve the problem - it helped me
That would seem to indicate your SkyConnect does not like
rtscts... strange, but you don't seem to be the only one... Does it work with 1.35.3-1 if you setrtscts: false(or remove the line entirely, it defaults to false if not provided)?
Under 135.1-1 it works with rtscts true and false under 135.2-1 and 135.3-1 neither.
This is a strange problem you are having.
With 1.35.2, that somewhat could make sense, if your adapter isn't supporting rtscts, before that (in 1.35.1), it would have been able to use xon/xoff, since both would have been enabled (which created problems with actual rtscts-enabled adapters). With 1.35.2, xon/xoff is only enabled if rtscts is false.
But from 1.35.2 to 1.35.3, there were no change to anything serial-related, and no change at all in ezsp... I would expect the behavior to be identical to 1.35.2 here...