ATM90E36_Arduino icon indicating copy to clipboard operation
ATM90E36_Arduino copied to clipboard

Wrong calculation of Checksums in CalibrationRegs.xlsx

Open Michi31 opened this issue 1 year ago • 0 comments

When calculation the HIGH WORD of the Checksums 0 - 3 only the last 7 digits are considered. It should be the last 8 digits!

E.g. in Sheet "Measurement Calibration" the formular in cell G39 should end with ... )));8)

Thanks for all your effort whatnick and igorgassv!

Michi31 avatar Dec 08 '23 14:12 Michi31