D1_mini_Examples
D1_mini_Examples copied to clipboard
Lolin D1 mini Pro 2.0 - what is LDO_EN ?
What is the jumper labeled LDO_EN is supposed to do on this board https://wiki.wemos.cc/products:d1:d1_mini_pro ?
See SJ2
under Power in the schematics. It’s normally not bridged and is so you can tie the EN pin to GND.
It’s the enable signal for the LDO regulator, active high.
Add a dab of solder to bridge the pads to disable the 5V regulator, so you can provide your own power source directly to the 3v3 and GND pins. Useful for battery operations.
thank you @mcauser I will try it. Still the CH340C would be powered on by the +3V3
You can wire a switch there, to turn the module on and off. It works perfectly. When off, it consumes 42 μΑ only. It's a pity this is not a proper connector.