Scaling problem in OverlayHistograms?
Hi Wouter,
we have noticed that the length violin plots do not necessarily fit with the Length Histograms when using several samples. Plots were created using v.1.22.0 but I tried the latest version and get the same results.
Here is an example showing the violin plots (the highlighted sample is also the one show in the next plot:
And here is the corresponding histogramm with all samples except only the circled one is shown:
Here we would expect a peak at 10Kb. And if I run NanoComp on only that one sample it seems to be doing it right:
Do you have any idea on what might be wrong or suggestions if I did something wrong? I am running it pretty vanilla NanoComp --outdir ./output --fastq *_ont.fastq.gz
Hi,
Just to be sure - in the last plot there is a peak at around 17kb - but you zoomed in too much in the histogram for 17kb. Is there a peak there?