I use ads1256 bcm python3 on rasperry4b, with 15000SPS and read data continuous mode. 使用树莓派4b python3 bcm模式, 15k采样率,连续读模式。

there appear some error voltage value sometimes. 经常会出现一些毛刺错误结果。 微信截图_20201219163657

微信截图_20201219163853

so,what is the reason? it is because the board or my program? 所以,到底是什么原因呢,是电路板自身的原因,还是我的程序有问题?

hustlong avatar Dec 19 '20 08:12 hustlong

微信截图_20201219164023

hustlong avatar Dec 19 '20 08:12 hustlong

These spikes indicate an incorrect value of the MSB, so they can be due to incorrect t6 and/or t11 delay (see ADS1256 datasheet).

astrocyte-medical avatar Aug 04 '21 23:08 astrocyte-medical