Sending continuous AT commands from a code
I've been trying to connect to AWS using a ESP32 with SIM7000G Firmware : 1351B05SIM7000A
This is the code that I'm using in the void loop part.
` modem.sendAT("+SMCONN"); if (modem.waitResponse(1000L, res) == 1) { res.replace(GSM_NL "OK" GSM_NL, ""); Serial.println(res); Serial.println("connection!!!!"); }
res="";
modem.sendAT("+SMPUB = "BasicPubSub", 425,0,0");
if (modem.waitResponse(10000L, res) == 1) { res.replace(GSM_NL "OK" GSM_NL, ""); Serial.println(res); Serial.println("datssent"); res="";
SerialAT.print(jsonBuffer);
}
modem.sendAT("+SMDISC");
if(modem.waitResponse(1000L,res) == 1)
{
Serial.println(res);
res="";
Serial.println("disconnectedf");
}
res="";
} `
The expected output at the AWS topic should be just the jsonBuffer,
{"state": {"desired": {"device_id":"device001" } } }
But this is the message that arrives on the topic on AWS
=================================================== `AT+SMCONN AT+SMPUB = "BasicPubSub", 425,0,0 {"state":{"desired": {"device_id":"device001"}}} AT+SMDISC AT+SMCONN
AT+SMPUB = "BasicPubSub", 425,0,0 {"state":{"desired": {"device_id":"device001"}}}
AT+SMDISC
AT+SMCONN
AT+SMPUB = "BasicPubSub", 425,0,0 {"state":{"desired": {"device_id":"device001"}}}
AT+SMDISC
AT+SMCONN
AT+SMPUB = "BasicPubSub", 425,0,0
AT+SMDISC`