Nikhil Choudhary

Results 39 comments of Nikhil Choudhary

Hi @kricon, >Thanks for creating and developing this project (...) I have some panels (PC5020, PC1565-2P, PC585) and modules (RF5132 v5, PC5104, few PC5108) available for testing and giving feedback...

> currently, I'm only able to access the specific battery level of zones by sending a *27## to the panel on initial start and retrieving it from the 0A (sent...

@kricon - Do you happen to have any logs showing the PC5204 outputs being activated/deactivated? I suspect this is in the 0x87 PGM output command (perhaps byte 3, bit 4-7)...

@kricon > I've verified PGMs 11-14 by connecting LEDs to outputs 1-4 of PC5204 which was connected onto keybus. But then idea came on my mind: why would you need...

> I also wanted to suggest ability to see PGM status in example sketches, for example in Home Assistance (device_class garage_door?) I've added PGM 1-14 status processing and updated the...

Hi @kricon, >So my question, is PC-16OUT PGM output really necessary or panels can work without them programmed, for example on PC1550 - how limited it would be without PC-16OUT...

> I was finally able to do some experiments with PC2550 V1.3R. The protocol seems to be the same, even the PC1500RK keypad works fine with it so it seems...

Hi @lubster85, >Mon Feb 7 14:25:19 2022 daemon.info hostapd: wlan1: STA xx:xx:xx:xx:xx:xx IEEE 802.11: deauthenticated due to inactivity (timer DEAUTH/REMOVE) Are you running OpenWRT on the router? Looks like there's...

Added MQTT example sketches and added features: * Set keypad beeps, 1-128 * Set keypad buzzer in seconds, 1-255 * Set keypad tone pattern with a number of beeps, an...

> Will this still work when the keypad is connected to the panel? e.g. Can we make the keypad beep? That would be quite handy for chime alerts. That'd be...