diyBMS-CurrentShunt
diyBMS-CurrentShunt copied to clipboard
Isolated current, voltage and SOC monitor for battery banks up to 85V
the shunt reset to 99% not to 100% looks like a bug. [Release-2023-01-25-12-26]
Hi Stuart, I am using the diybms with the original shunt, and its running really well. I do have a request though. Is there any chance we can have a...
I cannot seem to trigger the relay. See screenshot for configuration which i believe should be triggering at least three limits. 
Hi Stuart, I have trouble sourcing some of the parts for the CurrentShunt and wondered if you might have ideas where to buy. ADM2483BRWZ, ATTINY1614-SSNR, LM5009AMMX/NOPB, INA228AIDGSR are not available...
Hi, now i have detailed information about this issue. so first i have a 200A 60mV shunt in discharge mode current readings are correct to 20mV shunt voltage below this...
Hi, Any idea to drive (without too much work) 1 shunt per bank? Maybe the simple way is to have 1 contrôler per bank, but there is an easy way...
hi can you add a rule of ignoring negative current up to -1A if the battery is over the fully charge voltage? because my charge controller bounces in full status...
The "Basic Settings" for current & Voltage Monitoring allow me to save, but then those settings are not displayed, seeming as though they havn't been saved. In the logs modbus90_date.csv...
I have 55V set as fully charged voltage. And tail to 3 amps. It hit 55V, stayed around this voltage for 1 hour. Now inverter is going into "Float" at...
My system can pass over 180 amps. But I cannot set the over/under current limits to more than 127, and if I do, they become -127. 127+127 = 0xFF =...