randomness_testsuite
randomness_testsuite copied to clipboard
frequency test
Hi! You use function gammainc in your frequency test, but according to the NIST you must use "1 - gammainc"
Hi! The function gammainc
is correct as the P-value is equivalent to P(a,x)
, which in turn is equivalent to just using gammainc
. I think you are confusing P(a,x)
with Q(a,x)
as defined in section 5.5.3.