srsRAN_Project
srsRAN_Project copied to clipboard
Amarisoft UE Cannot Connect in O-RAN 7.2 Mode with Benetel RU550 Setup
Issue: Amarisoft UE Cannot Connect in O-RAN 7.2 Mode with Benetel RU550 Setup
Environment
- RU: Benetel RU550, firmware version:
RAN550-1v1.0.4-605a25a - DU: srsRAN DU server
- UE: Amarisoft UE
- Configuration Mode: O-RAN 7.2
- Clock Synchronization: Direct connection between RU and DU
Issue Description
The Amarisoft UE is unable to complete registration when operating in O-RAN 7.2 mode. While the UE can occasionally scan and detect the DU, it fails to complete the registration process. The RU and DU connection appears to be functioning properly based on synchronization logs and KPI metrics.
Setup Details
- The RU and DU server are directly connected to each other.
- Clock synchronization is implemented through a direct connection.
- Configuration was performed following the official srsRAN documentation at: https://docs.srsran.com/projects/project/en/latest/tutorials/source/oranRU/source/rus/r550.html
Current Status
- Clock synchronization has been successfully completed as confirmed by the logs:
root@benetelru:~# cat /tmp/logs/radio_sync_status
Configuring RU for PTP Sync mode.
PTP Settings configured
Directory /usr/lib/benetel OK
Directory /usr/lib/benetel/splane OK
Directory /usr/lib/benetel/splane/flags OK
todsync started
PTP4L started
PCM4L started
Syncmon started
Waiting for initial PTP sync...
PTP locked, synchronizing system time.
[INFO] Radio synchronized
- After starting the srsRAN program on the DU, the KPI metrics appear normal:
SAMPLE_TIME | RX_TOTAL | RX_ON_TIME | RX_EARLY | RX_LATE | RX_ON_TIME_C | RX_EARLY_C | RX_LATE_C | TX_TOTAL
04:16:48.571244 | 45127 | 41600 | -0 | -0 | 3402 | -0 | -0 | -0
04:16:49.584338 | 45011 | 41600 | -0 | -0 | 3420 | -0 | -0 | -0
04:16:50.582933 | 45048 | 41600 | -0 | -0 | 3398 | -0 | -0 | -0
04:16:51.612016 | 45052 | 41872 | -0 | -0 | 3492 | -0 | -0 | -0
Problem
Despite the successful RU-DU synchronization and apparently normal KPI metrics, the Amarisoft UE:
- Can only occasionally scan and detect the RU
- Cannot complete the registration process
- Cannot establish a connection in O-RAN 7.2 mode
Steps Already Taken
- Verified RU firmware version and confirmed it is the same as the guidance provided
- Followed the official srsRAN documentation for RU550 configuration
- Confirmed successful clock synchronization between RU and DU
- Verified normal KPI metrics on the DU
Attachments
I have attached all relevant configuration files and logs for reference.
ru_config.cfg.txt radio_setup_a.sh.txt gnb_ru_ran550_tdd_n78_100mhz_2x2.yml.txt 1chan-100mhz-ru.cfg.txt
Any guidance or suggestions would be greatly appreciated. Thank you!