Hi @wurmrobert , @jensenja As you have described, the reload config action waits until all devices finishes its polling to be able to do a safe-load runtime configuration on all...

Hi @toni-moreno If a measurement is indexed we must fillup the IndexTag with some information in order to identify the serie on InfluxDB. With that premise, using a metric to...

Hi @SnDsound , first of all, thanks for your detailed explanation! When you define an `IndexOID` it is expected that all the attached metrics use the same index as your...

Hello guys, First of all, sorry for the delayed response! We detected 2 needs on this issue: ### $VAL1 as index As you described quite well, @SnDsound , the first...

Hi @pmawsonau , apologies for the late answer As a first sight, it doesn't seem to be related with the SNMPCollector as itself, but we need the following information: -...

Hi @pmawsonau According to your configuration, the measurement index (mesurement walks + filters) will be each 5 hours, not 6 Anyway, we do not discard any SNMPCollector issue, so, please:...

A member of our team created a metric setup as `Gauge32 - INTEGER` and it was throwing an error trying to write the invalid point on InfluxDB. We have changed...

Hi @desa, I have been able to repro the issue, it seems to be related when loading JSON on template using -var function: This is my TICKScript: ```` ... var...

@nathanielc , @desa , are we doing something wrong? Thank you, Regards

Hi @Slach , to add more info, I found that on the following Grafana dashboard there is the same behaviour, as the legend values is different than the shown tooltip...