epanetCPA
epanetCPA copied to clipboard
Attack on Actuator
Hi @rtaormina! When I'm attacking a valve to inject false settings, as the example:
[CYBERATTACKS]
; Type, Target, Init_cond, End_cond, Arguments
Actuator, FCV1, TIME==20, TIME==30, 85
The settings changes during the attack, but at the end of the attack the original settings do not restored. From my experience the settings after the attack are replaced with the value of zero, what can cause a big mess in the WDN.
Do I doing it wrong or it is a bug? Anyway, for now this is my solution:
; FCV1 - original setting 90.3
Actuator, FCV1, TIME==20, TIME==30, 85
Actuator, FCV1, TIME==30, TIME==-1, 90.3
Thanks!
Thanks for pointing it out. I will look at it asap and let you know. It is true that valves are harder to handle with respect to pumps.