Roberto Panerai Velloso
Roberto Panerai Velloso
@plague-doctor on my inverter (SG4K) is: ``` - name: total_active_power hub: sungrow_sg4k slave: 1 count: 2 register: 5030 reverse_order: true register_type: input unit_of_measurement: W ``` But this only reports the...
I have a file sungrow sent me, it is supposed to work with all residential models. Its attached. It doesn't work for you? [TI_20190704_Communication Protocol for Residential Single-phase Grid-Connected Inverters_V10_EN.pdf](https://github.com/tjhowse/modbus4mqtt/files/5732710/TI_20190704_Communication.Protocol.for.Residential.Single-phase.Grid-Connected.Inverters_V10_EN.pdf)
https://github.com/tjhowse/modbus4mqtt/files/5732710/TI_20190704_Communication.Protocol.for.Residential.Single-phase.Grid-Connected.Inverters_V10_EN.pdf
It is 'minus one' says in the document Total active power 5031–5032 U32 W Note: Communication address = protocol address–1. If data of address 5000 is to be inquired, the...