stereopi-fisheye-robot icon indicating copy to clipboard operation
stereopi-fisheye-robot copied to clipboard

Error during step 4 calibration

Open wimg opened this issue 4 years ago • 3 comments

I'm getting errors during step 4 (calibration of the fisheye) : `$ python 4_calibration_fisheye.py Main cycle start Import pair No 1 Scale ratio: 0.5 Import pair No 2 Scale ratio: 0.5 Import pair No 3 Scale ratio: 0.5 Import pair No 4 Scale ratio: 0.5 Import pair No 5 Pair No 5 ignored, as no chessboard found Import pair No 6 Scale ratio: 0.5 Import pair No 7 Pair No 7 ignored, as no chessboard found Import pair No 8 Scale ratio: 0.5 Import pair No 9 Scale ratio: 0.5 Import pair No 10 Pair No 10 ignored, as no chessboard found Import pair No 11 Scale ratio: 0.5 Import pair No 12 Pair No 12 ignored, as no chessboard found Import pair No 13 Scale ratio: 0.5 Import pair No 14 Pair No 14 ignored, as no chessboard found Import pair No 15 Pair No 15 ignored, as no chessboard found Import pair No 16 Scale ratio: 0.5 Import pair No 17 Scale ratio: 0.5 Import pair No 18 Scale ratio: 0.5 Import pair No 19 Pair No 19 ignored, as no chessboard found Import pair No 20 Scale ratio: 0.5 Import pair No 21 Scale ratio: 0.5 Import pair No 22 Pair No 22 ignored, as no chessboard found Import pair No 23 Pair No 23 ignored, as no chessboard found Import pair No 24 Pair No 24 ignored, as no chessboard found Import pair No 25 Scale ratio: 0.5 Import pair No 26 Scale ratio: 0.5 Import pair No 27 Scale ratio: 0.5 Import pair No 28 Scale ratio: 0.5 Import pair No 29 Pair No 29 ignored, as no chessboard found Import pair No 30 Pair No 30 ignored, as no chessboard found End cycle Left camera calibration... Right camera calibration... Stereoscopic calibration... ./calibration_data/240p/camera_calibration_left.npz ['camera_matrix', 'distortion_coeff', 'imgpoints', 'map1', 'map2', 'objpoints'] Camera calibration data has been found in cache. ./calibration_data/240p/camera_calibration_right.npz ['camera_matrix', 'distortion_coeff', 'imgpoints', 'map1', 'map2', 'objpoints'] Camera calibration data has been found in cache. Calibrating cameras together... Traceback (most recent call last): File "4_calibration_fisheye.py", line 296, in result = calibrate_stereo_cameras() File "4_calibration_fisheye.py", line 254, in calibrate_stereo_cameras cv2.CALIB_FIX_INTRINSIC, TERMINATION_CRITERIA) cv2.error: OpenCV(3.4.4) /home/pi/packaging/opencv-python/opencv/modules/calib3d/src/fisheye.cpp:1420: error: (-3:Internal error) CALIB_CHECK_COND - Ill-conditioned matrix for input array 0 in function 'CalibrateExtrinsics'

$ `

Any idea what might be wrong ?

wimg avatar Oct 17 '20 18:10 wimg

This is the same situation for me, does anyone support us to solve this issue? Thank you.

TuanNguyenSKKU avatar Oct 24 '20 11:10 TuanNguyenSKKU

Hi @wimg and @TuanNguyenSKKU, This issue caused by images, where the chess corners are too close to the left side of the image. AFAIK, this is fixed in the latest OpenCV builds, but there are no stable builds of them on the PiWheels (used for OpenCV installation by pip). Please try this workaround. If it works for you, I will add this code to the 4th script.

realizator avatar Oct 26 '20 08:10 realizator

hi @realizator, Thank you so much.

TuanNguyenSKKU avatar Oct 26 '20 12:10 TuanNguyenSKKU