Is there a reason Qucs-S won't do a simple DC operating point (.op)? Qucs does it and I assume ngspice will do it as well.

If I add say a DC Parameter Sweep it does work.

Test_prj.zip

tomhajjar avatar Jul 29 '22 19:07 tomhajjar

I know about this problem. Qucs-S currently supports only F8 mode to show the .OP result. The single DC simulation device has no effect and the operation point is not saved to the dataset. See also #3

ra3xdh avatar Jul 29 '22 20:07 ra3xdh

Combined with #3

ra3xdh avatar Jul 30 '22 06:07 ra3xdh

Fixed via #513

ra3xdh avatar Feb 01 '24 11:02 ra3xdh