Installation parts do not have material description list

Open haubourg opened this issue 7 years ago • 3 comments

Data coming from other models have such material lists. SIA 405 references : for connection parts between pipes

  • "inconnu"
  • "acier"
  • "fonte"
  • "matiere_synthetique"

for tanks:

  • "inconnu"
  • "beton"
  • "fibrociment"
  • "amiante_ciment"
  • "metal"
  • "pierre"
  • "matiere_synthetique"

and some other values for special constructions

Should we extend current model with those values? SIA is very large and precise, adding all possible values is quite a work, but should better be done once than iteratively. @3nids @ponceta any opinion?

haubourg avatar Apr 24 '17 12:04 haubourg

@varrieta, feel free to add any other values you find here.

haubourg avatar Apr 24 '17 12:04 haubourg

In Pully we have https://gist.github.com/ponceta/e79fcd36ca611e559fd20fdcd9d84769.

ponceta avatar Apr 24 '17 13:04 ponceta

@ponceta yes, I had that in mind for pipes, but here we face a question about materials for ponctual objects likes installation parts (and probably more like tanks). Hydrants already have material in QWAT.