Open jaywilhelm opened this issue 6 years ago • 4 comments

Additions were made to enable the USB com port and process commands from a PC to assist with the length calibration. Text commands are send to load, increase, decrease, and unload the station instead of using the buttons. !D -> dump the calibration lengths !S #,# -> Save the position's length !CALI -> Start the calibration procedure !SETUP -> Enter the setup menu !DISABLE -> Turn off the steppers !L# -> Load the position !U -> Unload the position !INC -> Increment the current position that is loaded for calibration !DEC -> Decrease the current position that is loaded for calibration

jaywilhelm avatar Dec 24 '18 03:12 jaywilhelm

When these commands are in, it paves the path for calibration from the MK3(S) menu instead of buttons. Having a menu for filament lengths in stead of using the buttons (or serial commands) would be great.

ruedli avatar Mar 29 '19 11:03 ruedli

I performed the merge and got it to compile. This was for v1.0.3 and should get updated for the latest.

jaywilhelm avatar Mar 30 '19 01:03 jaywilhelm

So.... this is now also compatible with V1.05?

ruedli avatar Mar 30 '19 09:03 ruedli

Yes, it is compatible with v1.0.5. I have not had a chance to test yet.