collected metric was collected before with the same name and label values
Hello guys,
sorry for the long post, I am quite a novice to prometheus, so any help would be appreciated,
Host operating system: output of uname -a
Linux 5.15.0-91-generic #101-Ubuntu SMP x86_64 x86_64 x86_64 GNU/Linux
snmp_exporter version: output of snmp_exporter -version
snmp_exporter, version 0.25.0 (branch: HEAD, revision: 9c42d6c874d479314e612bca69558c81f8e26287) build user: root@880115266f70 build date: 20231210-10:05:18 go version: go1.21.5 platform: linux/amd64 tags: netgo
What device/snmpwalk OID are you using?
teraCPU
If this is a new device, please link to the MIB(s).
TERACPU-MIB DEFINITIONS ::= BEGIN
IMPORTS
enterprises FROM RFC1155-SMI
OBJECT-TYPE, Integer32 FROM SNMPv2-SMI;
ihse OBJECT IDENTIFIER ::= {enterprises 38034}
teracpu OBJECT IDENTIFIER ::= {ihse 1}
teraoem OBJECT IDENTIFIER ::= {teracpu 1}
teraconf OBJECT IDENTIFIER ::= {teracpu 2}
teratab OBJECT IDENTIFIER ::= {teracpu 3}
teravar OBJECT IDENTIFIER ::= {teracpu 4}
teratrap OBJECT IDENTIFIER ::= {teracpu 5}
DisplayString ::= OCTET STRING
teraCPU MODULE-IDENTITY
LAST-UPDATED "201602100000Z"
ORGANIZATION "IHSE GmbH"
CONTACT-INFO "[email protected]"
DESCRIPTION "The MIB module for managing the Draco tera devices"
REVISION "201602100000Z"
DESCRIPTION "Implementation of firmware version 3.02"
REVISION "201312020000Z"
DESCRIPTION "Implementation of firmware version 3.00"
REVISION "201305030000Z"
DESCRIPTION "Range of object teraSlotIndex changed from (0..65) to (0..64)"
REVISION "201301100000Z"
DESCRIPTION "Implementation of objects teraFan*, teraTrapFan*, teraPower* and teraTrapPower*"
REVISION "201211260000Z"
DESCRIPTION "Implementation of objects teraSwitch* and teraTrapSwitch"
REVISION "201211160000Z"
DESCRIPTION "Object teraTaskStatus extended"
REVISION "201211150000Z"
DESCRIPTION "Added support for Extender, CPU and CON data tables"
REVISION "201211140000Z"
DESCRIPTION "The initial relase"
::= {teracpu 10}
--
-- teraoem group
--
teraManufacturer OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION "Company name"
::= {teraoem 1}
teraFamily OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION "Product family"
::= {teraoem 2}
teraType OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION "Product type"
::= {teraoem 3}
--
-- teraconf group
--
teraName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION "Name of the configuration"
::= {teraconf 1}
teraInfo OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION "Description of the configuration"
::= {teraconf 2}
teraDevice OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION "Device name"
::= {teraconf 3}
--
-- teratab group
--
-- task data table
teraTaskTable OBJECT-TYPE
SYNTAX SEQUENCE OF teraTaskEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Task data table"
::= {teratab 1}
teraTaskEntry OBJECT-TYPE
SYNTAX teraTaskEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry of the task data table"
INDEX { teraTaskIndex }
::= {teraTaskTable 1}
teraTaskEntry ::=
SEQUENCE {
teraTaskIndex Integer32,
teraTaskName DisplayString,
teraTaskStatus INTEGER,
teraTaskCounter Integer32,
teraTaskCycle Integer32}
teraTaskIndex OBJECT-TYPE
SYNTAX Integer32(0..6)
ACCESS read-only
STATUS mandatory
DESCRIPTION "Task index (0..6)"
::= {teraTaskEntry 1}
teraTaskName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION "Task name"
::= {teraTaskEntry 2}
teraTaskStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
starting(1),
active(2),
busy(3),
waiting(4),
stopped(5),
error(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status information"
::= {teraTaskEntry 3}
teraTaskCounter OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS mandatory
DESCRIPTION "Performance counter"
::= {teraTaskEntry 4}
teraTaskCycle OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS mandatory
DESCRIPTION "Cycle time in microseconds"
::= {teraTaskEntry 5}
-- slot data table
teraSlotTable OBJECT-TYPE
SYNTAX SEQUENCE OF teraSlotEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Slot data table"
::= {teratab 2}
teraSlotEntry OBJECT-TYPE
SYNTAX teraSlotEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry of the slot data table"
INDEX { teraSlotIndex }
::= {teraSlotTable 1}
teraSlotEntry ::=
SEQUENCE {
teraSlotIndex Integer32,
teraSlotStatus Unsigned32,
teraSlotVersion DisplayString}
teraSlotIndex OBJECT-TYPE
SYNTAX Integer32(0..64)
ACCESS read-only
STATUS mandatory
DESCRIPTION "Slot index, 0 = CPU-Card, 1..64 = IO-Card"
::= {teraSlotEntry 1}
teraSlotStatus OBJECT-TYPE
SYNTAX Unsigned32
ACCESS read-only
STATUS mandatory
DESCRIPTION "Slot status
Bit 1 - 3 set: ready
Bit 4 set: active
Bit 27 set: error
Bit 31 set: module is on hold
Bit 32 set: module is invalid"
::= {teraSlotEntry 2}
teraSlotVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION "Type and firmware information"
::= {teraSlotEntry 3}
-- port data table
teraPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF teraPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Port data table"
::= {teratab 3}
teraPortEntry OBJECT-TYPE
SYNTAX teraPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry of the port data table"
INDEX { teraPortIndex }
::= {teraPortTable 1}
teraPortEntry ::=
SEQUENCE {
teraPortIndex Integer32,
teraPortStatus Unsigned32,
teraPortOutput Integer32,
teraPortExtenderIndex Integer32,
teraPortExtenderID Integer32}
teraPortIndex OBJECT-TYPE
SYNTAX Integer32(1..2032)
ACCESS read-only
STATUS mandatory
DESCRIPTION "Port index (1..2032)"
::= {teraPortEntry 1}
teraPortStatus OBJECT-TYPE
SYNTAX Unsigned32
ACCESS read-only
STATUS mandatory
DESCRIPTION "Port status
Bit 1-3 set: available but not in use
Bit 1-7 set: port connected
Bit 16 set: error"
::= {teraPortEntry 2}
teraPortOutput OBJECT-TYPE
SYNTAX Integer32(1..2032)
ACCESS read-only
STATUS mandatory
DESCRIPTION "Index of the port connected (0=not connected)"
::= {teraPortEntry 3}
teraPortExtenderIndex OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS mandatory
DESCRIPTION "Index of the extender connected"
::= {teraPortEntry 4}
teraPortExtenderID OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS mandatory
DESCRIPTION "ID of the extender connected"
::= {teraPortEntry 5}
-- extender data table
teraExtenderTable OBJECT-TYPE
SYNTAX SEQUENCE OF teraExtenderEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Extender data table"
::= {teratab 4}
teraExtenderEntry OBJECT-TYPE
SYNTAX teraExtenderEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry of the extender data table"
INDEX { teraExtenderIndex }
::= {teraExtenderTable 1}
teraExtenderEntry ::=
SEQUENCE {
teraExtenderIndex Integer32,
teraExtenderStatus OCTET STRING,
teraExtenderID Integer32,
teraExtenderType Unsigned32,
teraExtenderPort Integer32,
teraExtenderSPort Integer32,
teraExtenderCpuConIndex Integer32,
teraExtenderCpuConID Integer32,
teraExtenderCpuConType INTEGER}
teraExtenderIndex OBJECT-TYPE
SYNTAX Integer32(1..2048)
ACCESS read-only
STATUS mandatory
DESCRIPTION "Extender index (1..2048)"
::= {teraExtenderEntry 1}
teraExtenderStatus OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION "Extender status
Bit0=KVM1
Bit1=KVM2
Bit2=HID active
Bit3=HID1 device
Bit4=HID2 device
Bit5=HID sync
Bit6=Video1
Bit7=Video2"
::= {teraExtenderEntry 2}
teraExtenderID OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS mandatory
DESCRIPTION "Extender ID"
::= {teraExtenderEntry 3}
teraExtenderType OBJECT-TYPE
SYNTAX Unsigned32
ACCESS read-only
STATUS mandatory
DESCRIPTION "Extender type"
::= {teraExtenderEntry 4}
teraExtenderPort OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS mandatory
DESCRIPTION "Primary port index (0=not connected)"
::= {teraExtenderEntry 5}
teraExtenderSPort OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS mandatory
DESCRIPTION "Secondary port index (0=not connected)"
::= {teraExtenderEntry 6}
teraExtenderCpuConIndex OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS mandatory
DESCRIPTION "Index of the CPU/CON device assigned (0=not assigned)"
::= {teraExtenderEntry 7}
teraExtenderCpuConID OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS mandatory
DESCRIPTION "ID of the CPU/CON device assigned (0=not assigned)"
::= {teraExtenderEntry 8}
teraExtenderCpuConType OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
CPU(1),
CON(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Device type information 1=CPU 2=CON"
::= {teraExtenderEntry 9}
-- cpu data table
teraCpuTable OBJECT-TYPE
SYNTAX SEQUENCE OF teraCpuEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "CPU data table"
::= {teratab 5}
teraCpuEntry OBJECT-TYPE
SYNTAX teraCpuEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry of the CPU data table"
INDEX { teraCpuIndex }
::= {teraCpuTable 1}
teraCpuEntry ::=
SEQUENCE {
teraCpuIndex Integer32,
teraCpuStatus Unsigned32,
teraCpuID Integer32,
teraCpuRealCpuIndex Integer32,
teraCpuRealCpuID Integer32,
teraCpuConIndex Integer32,
teraCpuConID Integer32}
teraCpuIndex OBJECT-TYPE
SYNTAX Integer32(1..512)
ACCESS read-only
STATUS mandatory
DESCRIPTION "CPU index (1..512)"
::= {teraCpuEntry 1}
teraCpuStatus OBJECT-TYPE
SYNTAX Unsigned32
ACCESS read-only
STATUS mandatory
DESCRIPTION "CPU status
Bit 2 set: private mode connection
Bit 32 set: device has been defined"
::= {teraCpuEntry 2}
teraCpuID OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS mandatory
DESCRIPTION "CPU ID"
::= {teraCpuEntry 3}
teraCpuRealCpuIndex OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS mandatory
DESCRIPTION "For a virtual/real CPU device the index of the real/virtual CPU assigned"
::= {teraCpuEntry 4}
teraCpuRealCpuID OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS mandatory
DESCRIPTION "For a virtual/real CPU device the ID of the real/virtual CPU assigned"
::= {teraCpuEntry 5}
teraCpuConIndex OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS mandatory
DESCRIPTION "Index of the CON device connected (0=not connected)"
::= {teraCpuEntry 6}
teraCpuConID OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS mandatory
DESCRIPTION "ID of the CON device connected (0=not connected)"
::= {teraCpuEntry 7}
-- con data table
teraConTable OBJECT-TYPE
SYNTAX SEQUENCE OF teraConEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "CON data table"
::= {teratab 6}
teraConEntry OBJECT-TYPE
SYNTAX teraConEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry of the CON data table"
INDEX { teraConIndex }
::= {teraConTable 1}
teraConEntry ::=
SEQUENCE {
teraConIndex Integer32,
teraConStatus Unsigned32,
teraConID Integer32,
teraConVirtualConIndex Integer32,
teraConVirtualConID Integer32,
teraConCpuIndex Integer32,
teraConCpuID Integer32}
teraConIndex OBJECT-TYPE
SYNTAX Integer32(1..512)
ACCESS read-only
STATUS mandatory
DESCRIPTION "CON index (1..512)"
::= {teraConEntry 1}
teraConStatus OBJECT-TYPE
SYNTAX Unsigned32
ACCESS read-only
STATUS mandatory
DESCRIPTION "CON status
Bit 2 set: private mode connection
Bit 3 set: video only connection
Bit 32 set: device has been defined"
::= {teraConEntry 2}
teraConID OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS mandatory
DESCRIPTION "CON ID"
::= {teraConEntry 3}
teraConVirtualConIndex OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS mandatory
DESCRIPTION "For a real CON device the index of the virtual CON assigned"
::= {teraConEntry 4}
teraConVirtualConID OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS mandatory
DESCRIPTION "For a real CON device the ID of the virtual CON assigned"
::= {teraConEntry 5}
teraConCpuIndex OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS mandatory
DESCRIPTION "Index of the CPU device connected (0=not connected)"
::= {teraConEntry 6}
teraConCpuID OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS mandatory
DESCRIPTION "ID of the CPU device connected (0=not connected)"
::= {teraConEntry 7}
--
-- teravar group
--
teraStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
active(1),
disabled(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of the matrix chip"
::= {teravar 1}
teraTemperature OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS mandatory
DESCRIPTION "Temperature of the matrix chip
recommended temperature: < 110°C
maximum temperature: 130°C"
::= {teravar 2}
teraInsertSlot OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS mandatory
DESCRIPTION "Last slot inserted"
::= {teravar 10}
teraRemoveSlot OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS mandatory
DESCRIPTION "Last slot removed"
::= {teravar 11}
teraInvalidSlot OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS mandatory
DESCRIPTION "Last slot marked as invalid"
::= {teravar 12}
teraInsertExtender OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS mandatory
DESCRIPTION "Last extender inserted"
::= {teravar 20}
teraRemoveExtender OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS mandatory
DESCRIPTION "Last extender removed"
::= {teravar 21}
teraSwitchFromUser OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS mandatory
DESCRIPTION "User ID"
::= {teravar 30}
teraSwitchFromCon OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS mandatory
DESCRIPTION "CON ID"
::= {teravar 31}
teraSwitchCpu OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS mandatory
DESCRIPTION "CPU ID to connect"
::= {teravar 32}
teraSwitchCon OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS mandatory
DESCRIPTION "CON ID to connect"
::= {teravar 33}
teraSwitchMode OBJECT-TYPE
SYNTAX INTEGER {
Standard(0),
VideoOnly(1),
Private(2),
ControlOnly(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Mode how to connect"
::= {teravar 34}
teraFan1Status OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
okay(1),
faulty(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of fan tray #1"
::= {teravar 40}
teraFan1Speed OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS mandatory
DESCRIPTION "Speed of fan tray #1 in steps
min: 0, max: 15"
::= {teravar 41}
teraFan2Status OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
okay(1),
faulty(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of fan tray #2"
::= {teravar 42}
teraFan2Speed OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS mandatory
DESCRIPTION "Speed of fan tray #2 in steps
min: 0, max: 15"
::= {teravar 43}
teraPower1Status OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
available(1),
power(3),
faulty(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of power supply #1"
::= {teravar 50}
teraPower2Status OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
available(1),
power(3),
faulty(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of power supply #2"
::= {teravar 51}
teraPower3Status OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
available(1),
power(3),
faulty(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of power supply #3"
::= {teravar 52}
teraPower4Status OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
available(1),
power(3),
faulty(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of power supply #4"
::= {teravar 53}
teraExtenderPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Extender port"
::= {teravar 60}
teraExtenderID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Extender ID"
::= {teravar 61}
--
teraExtenderStatus OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION "Extender status"
::= {teravar 62}
-- teratrap group
--
teraTrapList OBJECT-IDENTITY
STATUS current
DESCRIPTION "Notification objects"
::= {teratrap 0}
teraTrapStatus NOTIFICATION-TYPE
OBJECTS { teraStatus }
STATUS current
DESCRIPTION "Status of the matrix"
::= {teraTrapList 1}
teraTrapTemperature NOTIFICATION-TYPE
OBJECTS { teraTemperature }
STATUS current
DESCRIPTION "Temperature of the matrix chip
recommended temperature: <110°C
maximum temperature: 130°C"
::= {teraTrapList 2}
teraTrapInsertSlot NOTIFICATION-TYPE
OBJECTS { teraInsertSlot }
STATUS current
DESCRIPTION "Last slot inserted"
::= {teraTrapList 10}
teraTrapRemoveSlot NOTIFICATION-TYPE
OBJECTS { teraRemoveSlot }
STATUS current
DESCRIPTION "Last slot removed"
::= {teraTrapList 11}
teraTrapInvalidSlot NOTIFICATION-TYPE
OBJECTS { teraInvalidSlot }
STATUS current
DESCRIPTION "Last slot marked as invalid"
::= {teraTrapList 12}
teraTrapInsertExtender NOTIFICATION-TYPE
OBJECTS { teraInsertExtender }
STATUS current
DESCRIPTION "Last extender inserted"
::= {teraTrapList 20}
teraTrapRemoveExtender NOTIFICATION-TYPE
OBJECTS { teraRemoveExtender }
STATUS current
DESCRIPTION "Last extender removed"
::= {teraTrapList 21}
teraTrapSwitch NOTIFICATION-TYPE
OBJECTS { teraSwitchFromUser,
teraSwitchFromCon,
teraSwitchCpu,
teraSwitchCon,
teraSwitchMode }
STATUS current
DESCRIPTION "Switch command"
::= {teraTrapList 30}
teraTrapFan1 NOTIFICATION-TYPE
OBJECTS { teraFan1Status,
teraFan1Speed }
STATUS current
DESCRIPTION "Status and speed of fan tray #1"
::= {teraTrapList 40}
teraTrapFan2 NOTIFICATION-TYPE
OBJECTS { teraFan2Status,
teraFan2Speed }
STATUS current
DESCRIPTION "Status and speed of fan tray #2"
::= {teraTrapList 41}
teraTrapPower1 NOTIFICATION-TYPE
OBJECTS { teraPower1Status }
STATUS current
DESCRIPTION "Status of power supply #1"
::= {teraTrapList 50}
teraTrapPower2 NOTIFICATION-TYPE
OBJECTS { teraPower2Status }
STATUS current
DESCRIPTION "Status of power supply #2"
::= {teraTrapList 51}
teraTrapPower3 NOTIFICATION-TYPE
OBJECTS { teraPower3Status }
STATUS current
DESCRIPTION "Status of power supply #3"
::= {teraTrapList 52}
teraTrapPower4 NOTIFICATION-TYPE
OBJECTS { teraPower4Status }
STATUS current
DESCRIPTION "Status of power supply #4"
::= {teraTrapList 53}
teraTrapExtenderStatus NOTIFICATION-TYPE
OBJECTS { teraExtenderPort,
teraExtenderID,
teraExtenderStatus }
STATUS current
DESCRIPTION "Extender status
Bit0=KVM1
Bit1=KVM2
Bit2=HID active
Bit3=HID1 device
Bit4=HID2 device
Bit5=HID sync
Bit6=Video1
Bit7=Video2"
::= {teraTrapList 60}
END
What did you do that produced an error?
I generated the snmp.yml config using the generator and specifying to walk teraoem, teraconf, teratab, tearavar
What did you expect to see?
metrics from the label
What did you see instead?
An error has occurred while serving metrics:
8 error(s) occurred:
- collected metric "teraTaskStatus" { label:{name:"teraTaskIndex" value:"0"} gauge:{value:4}} was collected before with the same name and label values
- collected metric "teraSlotVersion" { label:{name:"teraSlotIndex" value:"0"} label:{name:"teraSlotVersion" value:"MATL048 CPU 1 F04.04 24.08.23"} gauge:{value:1}} was collected before with the same name and label values
- collected metric "teraTaskCycle" { label:{name:"teraTaskIndex" value:"0"} gauge:{value:365}} was collected before with the same name and label values
- collected metric "teraTaskIndex" { label:{name:"teraTaskIndex" value:"0"} gauge:{value:0}} was collected before with the same name and label values
- collected metric "teraTaskName" { label:{name:"teraTaskIndex" value:"0"} label:{name:"teraTaskName" value:"taskMAIN"} gauge:{value:1}} was collected before with the same name and label values
- collected metric "teraSlotStatus" { label:{name:"teraSlotIndex" value:"0"} gauge:{value:15}} was collected before with the same name and label values
- collected metric "teraTaskCounter" { label:{name:"teraTaskIndex" value:"0"} gauge:{value:2.13197e+06}} was collected before with the same name and label values
- collected metric "teraSlotIndex" { label:{name:"teraSlotIndex" value:"0"} gauge:{value:0}} was collected before with the same name and label values
if i remove teratab i get the metrics correct, so i guess the problem is there...
### generator.yml file:
auths:
auth_name:
version: 2 # SNMP version to use. Defaults to 2.
# 1 will use GETNEXT, 2 and 3 use GETBULK.
# Community string is used with SNMP v1 and v2. Defaults to "public".
community: xxxx
modules:
teraCPU: # The module name. You can have as many modules as you want.
walk: # List of OIDs to walk. Can also be SNMP object names or specific instances.
- teraoem
- teraconf
- teratab
- teravar
- teratrap
max_repetitions: 25 # How many objects to request with GET/GETBULK, defaults to 25.
# May need to be reduced for buggy devices.
retries: 3 # How many times to retry a failed request, defaults to 3.
timeout: 5s # Timeout for each individual SNMP request, defaults to 5s.
lookups:
- source_indexes: [ifIndex]
lookup: ifAlias
- source_indexes: [ifIndex]
lookup: ifDescr
### snmp.yml file:
# WARNING: This file was auto-generated using snmp_exporter generator, manual changes will be lost.
auths:
auth_name:
community: xxxx
security_level: noAuthNoPriv
auth_protocol: MD5
priv_protocol: DES
version: 2
modules:
teraCPU:
walk:
- 1.3.6.1.4.1.38034.1.1
- 1.3.6.1.4.1.38034.1.2
- 1.3.6.1.4.1.38034.1.3
- 1.3.6.1.4.1.38034.1.4
- 1.3.6.1.4.1.38034.1.5
metrics:
- name: teraManufacturer
oid: 1.3.6.1.4.1.38034.1.1.1
type: DisplayString
help: Company name - 1.3.6.1.4.1.38034.1.1.1
- name: teraFamily
oid: 1.3.6.1.4.1.38034.1.1.2
type: DisplayString
help: Product family - 1.3.6.1.4.1.38034.1.1.2
- name: teraType
oid: 1.3.6.1.4.1.38034.1.1.3
type: DisplayString
help: Product type - 1.3.6.1.4.1.38034.1.1.3
- name: teraName
oid: 1.3.6.1.4.1.38034.1.2.1
type: DisplayString
help: Name of the configuration - 1.3.6.1.4.1.38034.1.2.1
- name: teraInfo
oid: 1.3.6.1.4.1.38034.1.2.2
type: DisplayString
help: Description of the configuration - 1.3.6.1.4.1.38034.1.2.2
- name: teraDevice
oid: 1.3.6.1.4.1.38034.1.2.3
type: DisplayString
help: Device name - 1.3.6.1.4.1.38034.1.2.3
- name: teraTaskIndex
oid: 1.3.6.1.4.1.38034.1.3.1.1.1
type: gauge
help: Task index (0..6) - 1.3.6.1.4.1.38034.1.3.1.1.1
indexes:
- labelname: teraTaskIndex
type: gauge
- name: teraTaskName
oid: 1.3.6.1.4.1.38034.1.3.1.1.2
type: DisplayString
help: Task name - 1.3.6.1.4.1.38034.1.3.1.1.2
indexes:
- labelname: teraTaskIndex
type: gauge
- name: teraTaskStatus
oid: 1.3.6.1.4.1.38034.1.3.1.1.3
type: gauge
help: Status information - 1.3.6.1.4.1.38034.1.3.1.1.3
indexes:
- labelname: teraTaskIndex
type: gauge
enum_values:
0: unknown
1: starting
2: active
3: busy
4: waiting
5: stopped
6: error
- name: teraTaskCounter
oid: 1.3.6.1.4.1.38034.1.3.1.1.4
type: gauge
help: Performance counter - 1.3.6.1.4.1.38034.1.3.1.1.4
indexes:
- labelname: teraTaskIndex
type: gauge
- name: teraTaskCycle
oid: 1.3.6.1.4.1.38034.1.3.1.1.5
type: gauge
help: Cycle time in microseconds - 1.3.6.1.4.1.38034.1.3.1.1.5
indexes:
- labelname: teraTaskIndex
type: gauge
- name: teraSlotIndex
oid: 1.3.6.1.4.1.38034.1.3.2.1.1
type: gauge
help: Slot index, 0 = CPU-Card, 1..64 = IO-Card - 1.3.6.1.4.1.38034.1.3.2.1.1
indexes:
- labelname: teraSlotIndex
type: gauge
- name: teraSlotStatus
oid: 1.3.6.1.4.1.38034.1.3.2.1.2
type: gauge
help: 'Slot status Bit 1 - 3 set: ready Bit 4 set: active Bit 27 set: error
Bit 31 set: module is on hold Bit 32 set: module is invalid - 1.3.6.1.4.1.38034.1.3.2.1.2'
indexes:
- labelname: teraSlotIndex
type: gauge
- name: teraSlotVersion
oid: 1.3.6.1.4.1.38034.1.3.2.1.3
type: DisplayString
help: Type and firmware information - 1.3.6.1.4.1.38034.1.3.2.1.3
indexes:
- labelname: teraSlotIndex
type: gauge
- name: teraPortIndex
oid: 1.3.6.1.4.1.38034.1.3.3.1.1
type: gauge
help: Port index (1..2032) - 1.3.6.1.4.1.38034.1.3.3.1.1
indexes:
- labelname: teraPortIndex
type: gauge
- name: teraPortStatus
oid: 1.3.6.1.4.1.38034.1.3.3.1.2
type: gauge
help: 'Port status Bit 1-3 set: available but not in use Bit 1-7 set: port connected
Bit 16 set: error - 1.3.6.1.4.1.38034.1.3.3.1.2'
indexes:
- labelname: teraPortIndex
type: gauge
- name: teraPortOutput
oid: 1.3.6.1.4.1.38034.1.3.3.1.3
type: gauge
help: Index of the port connected (0=not connected) - 1.3.6.1.4.1.38034.1.3.3.1.3
indexes:
- labelname: teraPortIndex
type: gauge
- name: teraPortExtenderIndex
oid: 1.3.6.1.4.1.38034.1.3.3.1.4
type: gauge
help: Index of the extender connected - 1.3.6.1.4.1.38034.1.3.3.1.4
indexes:
- labelname: teraPortIndex
type: gauge
- name: teraPortExtenderID
oid: 1.3.6.1.4.1.38034.1.3.3.1.5
type: gauge
help: ID of the extender connected - 1.3.6.1.4.1.38034.1.3.3.1.5
indexes:
- labelname: teraPortIndex
type: gauge
- name: teraExtenderIndex
oid: 1.3.6.1.4.1.38034.1.3.4.1.1
type: gauge
help: Extender index (1..2048) - 1.3.6.1.4.1.38034.1.3.4.1.1
indexes:
- labelname: teraExtenderIndex
type: gauge
- name: teraExtenderStatus
oid: 1.3.6.1.4.1.38034.1.3.4.1.2
type: OctetString
help: Extender status Bit0=KVM1 Bit1=KVM2 Bit2=HID active Bit3=HID1 device Bit4=HID2
device Bit5=HID sync Bit6=Video1 Bit7=Video2 - 1.3.6.1.4.1.38034.1.3.4.1.2
indexes:
- labelname: teraExtenderIndex
type: gauge
- name: teraExtenderID
oid: 1.3.6.1.4.1.38034.1.3.4.1.3
type: gauge
help: Extender ID - 1.3.6.1.4.1.38034.1.3.4.1.3
indexes:
- labelname: teraExtenderIndex
type: gauge
- name: teraExtenderType
oid: 1.3.6.1.4.1.38034.1.3.4.1.4
type: gauge
help: Extender type - 1.3.6.1.4.1.38034.1.3.4.1.4
indexes:
- labelname: teraExtenderIndex
type: gauge
- name: teraExtenderPort
oid: 1.3.6.1.4.1.38034.1.3.4.1.5
type: gauge
help: Primary port index (0=not connected) - 1.3.6.1.4.1.38034.1.3.4.1.5
indexes:
- labelname: teraExtenderIndex
type: gauge
- name: teraExtenderSPort
oid: 1.3.6.1.4.1.38034.1.3.4.1.6
type: gauge
help: Secondary port index (0=not connected) - 1.3.6.1.4.1.38034.1.3.4.1.6
indexes:
- labelname: teraExtenderIndex
type: gauge
- name: teraExtenderCpuConIndex
oid: 1.3.6.1.4.1.38034.1.3.4.1.7
type: gauge
help: Index of the CPU/CON device assigned (0=not assigned) - 1.3.6.1.4.1.38034.1.3.4.1.7
indexes:
- labelname: teraExtenderIndex
type: gauge
- name: teraExtenderCpuConID
oid: 1.3.6.1.4.1.38034.1.3.4.1.8
type: gauge
help: ID of the CPU/CON device assigned (0=not assigned) - 1.3.6.1.4.1.38034.1.3.4.1.8
indexes:
- labelname: teraExtenderIndex
type: gauge
- name: teraExtenderCpuConType
oid: 1.3.6.1.4.1.38034.1.3.4.1.9
type: gauge
help: Device type information 1=CPU 2=CON - 1.3.6.1.4.1.38034.1.3.4.1.9
indexes:
- labelname: teraExtenderIndex
type: gauge
enum_values:
0: unknown
1: CPU
2: CON
- name: teraCpuIndex
oid: 1.3.6.1.4.1.38034.1.3.5.1.1
type: gauge
help: CPU index (1..512) - 1.3.6.1.4.1.38034.1.3.5.1.1
indexes:
- labelname: teraCpuIndex
type: gauge
- name: teraCpuStatus
oid: 1.3.6.1.4.1.38034.1.3.5.1.2
type: gauge
help: 'CPU status Bit 2 set: private mode connection Bit 32 set: device has
been defined - 1.3.6.1.4.1.38034.1.3.5.1.2'
indexes:
- labelname: teraCpuIndex
type: gauge
- name: teraCpuID
oid: 1.3.6.1.4.1.38034.1.3.5.1.3
type: gauge
help: CPU ID - 1.3.6.1.4.1.38034.1.3.5.1.3
indexes:
- labelname: teraCpuIndex
type: gauge
- name: teraCpuRealCpuIndex
oid: 1.3.6.1.4.1.38034.1.3.5.1.4
type: gauge
help: For a virtual/real CPU device the index of the real/virtual CPU assigned
- 1.3.6.1.4.1.38034.1.3.5.1.4
indexes:
- labelname: teraCpuIndex
type: gauge
- name: teraCpuRealCpuID
oid: 1.3.6.1.4.1.38034.1.3.5.1.5
type: gauge
help: For a virtual/real CPU device the ID of the real/virtual CPU assigned
- 1.3.6.1.4.1.38034.1.3.5.1.5
indexes:
- labelname: teraCpuIndex
type: gauge
- name: teraCpuConIndex
oid: 1.3.6.1.4.1.38034.1.3.5.1.6
type: gauge
help: Index of the CON device connected (0=not connected) - 1.3.6.1.4.1.38034.1.3.5.1.6
indexes:
- labelname: teraCpuIndex
type: gauge
- name: teraCpuConID
oid: 1.3.6.1.4.1.38034.1.3.5.1.7
type: gauge
help: ID of the CON device connected (0=not connected) - 1.3.6.1.4.1.38034.1.3.5.1.7
indexes:
- labelname: teraCpuIndex
type: gauge
- name: teraConIndex
oid: 1.3.6.1.4.1.38034.1.3.6.1.1
type: gauge
help: CON index (1..512) - 1.3.6.1.4.1.38034.1.3.6.1.1
indexes:
- labelname: teraConIndex
type: gauge
- name: teraConStatus
oid: 1.3.6.1.4.1.38034.1.3.6.1.2
type: gauge
help: 'CON status Bit 2 set: private mode connection Bit 3 set: video only connection
Bit 32 set: device has been defined - 1.3.6.1.4.1.38034.1.3.6.1.2'
indexes:
- labelname: teraConIndex
type: gauge
- name: teraConID
oid: 1.3.6.1.4.1.38034.1.3.6.1.3
type: gauge
help: CON ID - 1.3.6.1.4.1.38034.1.3.6.1.3
indexes:
- labelname: teraConIndex
type: gauge
- name: teraConVirtualConIndex
oid: 1.3.6.1.4.1.38034.1.3.6.1.4
type: gauge
help: For a real CON device the index of the virtual CON assigned - 1.3.6.1.4.1.38034.1.3.6.1.4
indexes:
- labelname: teraConIndex
type: gauge
- name: teraConVirtualConID
oid: 1.3.6.1.4.1.38034.1.3.6.1.5
type: gauge
help: For a real CON device the ID of the virtual CON assigned - 1.3.6.1.4.1.38034.1.3.6.1.5
indexes:
- labelname: teraConIndex
type: gauge
- name: teraConCpuIndex
oid: 1.3.6.1.4.1.38034.1.3.6.1.6
type: gauge
help: Index of the CPU device connected (0=not connected) - 1.3.6.1.4.1.38034.1.3.6.1.6
indexes:
- labelname: teraConIndex
type: gauge
- name: teraConCpuID
oid: 1.3.6.1.4.1.38034.1.3.6.1.7
type: gauge
help: ID of the CPU device connected (0=not connected) - 1.3.6.1.4.1.38034.1.3.6.1.7
indexes:
- labelname: teraConIndex
type: gauge
- name: teraStatus
oid: 1.3.6.1.4.1.38034.1.4.1
type: gauge
help: Status of the matrix chip - 1.3.6.1.4.1.38034.1.4.1
enum_values:
0: unknown
1: active
2: disabled
- name: teraTemperature
oid: 1.3.6.1.4.1.38034.1.4.2
type: gauge
help: 'Temperature of the matrix chip recommended temperature: < 110°C maximum
temperature: 130°C - 1.3.6.1.4.1.38034.1.4.2'
- name: teraInsertSlot
oid: 1.3.6.1.4.1.38034.1.4.10
type: gauge
help: Last slot inserted - 1.3.6.1.4.1.38034.1.4.10
- name: teraRemoveSlot
oid: 1.3.6.1.4.1.38034.1.4.11
type: gauge
help: Last slot removed - 1.3.6.1.4.1.38034.1.4.11
- name: teraInvalidSlot
oid: 1.3.6.1.4.1.38034.1.4.12
type: gauge
help: Last slot marked as invalid - 1.3.6.1.4.1.38034.1.4.12
- name: teraInsertExtender
oid: 1.3.6.1.4.1.38034.1.4.20
type: gauge
help: Last extender inserted - 1.3.6.1.4.1.38034.1.4.20
- name: teraRemoveExtender
oid: 1.3.6.1.4.1.38034.1.4.21
type: gauge
help: Last extender removed - 1.3.6.1.4.1.38034.1.4.21
- name: teraSwitchFromUser
oid: 1.3.6.1.4.1.38034.1.4.30
type: gauge
help: User ID - 1.3.6.1.4.1.38034.1.4.30
- name: teraSwitchFromCon
oid: 1.3.6.1.4.1.38034.1.4.31
type: gauge
help: CON ID - 1.3.6.1.4.1.38034.1.4.31
- name: teraSwitchCpu
oid: 1.3.6.1.4.1.38034.1.4.32
type: gauge
help: CPU ID to connect - 1.3.6.1.4.1.38034.1.4.32
- name: teraSwitchCon
oid: 1.3.6.1.4.1.38034.1.4.33
type: gauge
help: CON ID to connect - 1.3.6.1.4.1.38034.1.4.33
- name: teraSwitchMode
oid: 1.3.6.1.4.1.38034.1.4.34
type: gauge
help: Mode how to connect - 1.3.6.1.4.1.38034.1.4.34
enum_values:
0: Standard
1: VideoOnly
2: Private
3: ControlOnly
- name: teraFan1Status
oid: 1.3.6.1.4.1.38034.1.4.40
type: gauge
help: 'Status of fan tray #1 - 1.3.6.1.4.1.38034.1.4.40'
enum_values:
0: unknown
1: okay
2: faulty
- name: teraFan1Speed
oid: 1.3.6.1.4.1.38034.1.4.41
type: gauge
help: 'Speed of fan tray #1 in steps min: 0, max: 15 - 1.3.6.1.4.1.38034.1.4.41'
- name: teraFan2Status
oid: 1.3.6.1.4.1.38034.1.4.42
type: gauge
help: 'Status of fan tray #2 - 1.3.6.1.4.1.38034.1.4.42'
enum_values:
0: unknown
1: okay
2: faulty
- name: teraFan2Speed
oid: 1.3.6.1.4.1.38034.1.4.43
type: gauge
help: 'Speed of fan tray #2 in steps min: 0, max: 15 - 1.3.6.1.4.1.38034.1.4.43'
- name: teraPower1Status
oid: 1.3.6.1.4.1.38034.1.4.50
type: gauge
help: 'Status of power supply #1 - 1.3.6.1.4.1.38034.1.4.50'
enum_values:
0: unknown
1: available
3: power
4: faulty
- name: teraPower2Status
oid: 1.3.6.1.4.1.38034.1.4.51
type: gauge
help: 'Status of power supply #2 - 1.3.6.1.4.1.38034.1.4.51'
enum_values:
0: unknown
1: available
3: power
4: faulty
- name: teraPower3Status
oid: 1.3.6.1.4.1.38034.1.4.52
type: gauge
help: 'Status of power supply #3 - 1.3.6.1.4.1.38034.1.4.52'
enum_values:
0: unknown
1: available
3: power
4: faulty
- name: teraPower4Status
oid: 1.3.6.1.4.1.38034.1.4.53
type: gauge
help: 'Status of power supply #4 - 1.3.6.1.4.1.38034.1.4.53'
enum_values:
0: unknown
1: available
3: power
4: faulty
- name: teraExtenderPort
oid: 1.3.6.1.4.1.38034.1.4.60
type: gauge
help: Extender port - 1.3.6.1.4.1.38034.1.4.60
- name: teraExtenderID
oid: 1.3.6.1.4.1.38034.1.4.61
type: gauge
help: Extender ID - 1.3.6.1.4.1.38034.1.4.61
- name: teraExtenderStatus
oid: 1.3.6.1.4.1.38034.1.4.62
type: OctetString
help: Extender status - 1.3.6.1.4.1.38034.1.4.62
max_repetitions: 25
retries: 3
timeout: 5s
Can you provide the output of a net-snmp snmpwalk for the OID teraTaskStatus / 1.3.6.1.4.1.38034.1.3.1.1.3? My first guess is that this is a device bug, the MIB says one thing, but the device is responding with invalid data.
One thing about your generator.yml, what you actually want to use instead of teratab (this is an index) is the OID for the table, teraTaskTable. I don't think this is actually causing a problem, but it's more intuitive if you use the OID for the table, not the index.
Hi SuperQ, Thanks for your response, here is the snmpwalk for 1.3.6.1.4.1.38034.1.3.1.1.3
SNMPv2-SMI::enterprises.38034.1.3.1.1.3.0 = INTEGER: 4 SNMPv2-SMI::enterprises.38034.1.3.1.1.3.1 = INTEGER: 4 SNMPv2-SMI::enterprises.38034.1.3.1.1.3.2 = INTEGER: 4 SNMPv2-SMI::enterprises.38034.1.3.1.1.3.3 = INTEGER: 4 SNMPv2-SMI::enterprises.38034.1.3.1.1.3.4 = INTEGER: 4 SNMPv2-SMI::enterprises.38034.1.3.1.1.3.5 = INTEGER: 4 SNMPv2-SMI::enterprises.38034.1.3.1.1.3.6 = INTEGER: 5 SNMPv2-SMI::enterprises.38034.1.3.1.1.3.7 = INTEGER: 4 SNMPv2-SMI::enterprises.38034.1.3.1.1.3.8 = INTEGER: 2 SNMPv2-SMI::enterprises.38034.1.3.1.1.3.9 = INTEGER: 1 SNMPv2-SMI::enterprises.38034.1.3.1.1.3.10 = INTEGER: 5 SNMPv2-SMI::enterprises.38034.1.3.1.1.3.11 = INTEGER: 4 SNMPv2-SMI::enterprises.38034.1.3.1.1.3.12 = INTEGER: 4
regarding the teratab, you probably right, though it didn't solve the errors...
What if you have this generator walk list that doesn't include the Task table?
modules:
teraCPU: # The module name. You can have as many modules as you want.
walk: # List of OIDs to walk. Can also be SNMP object names or specific instances.
- teraManufacturer
- teraFamily
- teraType
- teraName
- teraInfo
- teraDevice
- teraSlotTable
- teraPortTable
ok, so the snmp.yml looks like
walk:
- 1.3.6.1.4.1.38034.1.3.2
- 1.3.6.1.4.1.38034.1.3.3
get:
- 1.3.6.1.4.1.38034.1.1.1.0
- 1.3.6.1.4.1.38034.1.1.2.0
- 1.3.6.1.4.1.38034.1.1.3.0
- 1.3.6.1.4.1.38034.1.2.1.0
- 1.3.6.1.4.1.38034.1.2.2.0
- 1.3.6.1.4.1.38034.1.2.3.0
and snmp exporter is still not happy:
An error has occurred while serving metrics:
3 error(s) occurred:
- collected metric "teraSlotVersion" { label:{name:"teraSlotIndex" value:"0"} label:{name:"teraSlotVersion" value:"MATL048 CPU 1 F04.04 24.08.23"} gauge:{value:1}} was collected before with the same name and label values
- collected metric "teraSlotStatus" { label:{name:"teraSlotIndex" value:"0"} gauge:{value:15}} was collected before with the same name and label values
- collected metric "teraSlotIndex" { label:{name:"teraSlotIndex" value:"0"} gauge:{value:0}} was collected before with the same name and label values
That makes no sense, given the snmpwalk output. What is your Prometheus configuration? Do you get the same result if you curl the exporter?
A tcpdump capture and comparison between snmpwalk and the exporter may be necessary.
prometheus.yml:
global:
scrape_interval: 15s # By default, scrape targets every 15 seconds.
# Attach these labels to any time series or alerts when communicating with
# external systems (federation, remote storage, Alertmanager).
# A scrape configuration containing exactly one endpoint to scrape:
# Here it's Prometheus itself.
scrape_configs:
# The job name is added as a label `job=<job_name>` to any timeseries scraped from this config.
- job_name: snmp_IHSE
metrics_path: /snmp
params:
auth: [auth_name]
module: [teraCPU]
static_configs:
- targets:
- 192.168.1.91
relabel_configs:
- source_labels: [__address__]
target_label: __param_target
- source_labels: [__param_target]
target_label: instance
- target_label: __address__
replacement: 127.0.0.1:9116 # URL as shown on the UI
same results when i curl the exporter
curl 'localhost:9116/snmp?target=x.x.x.x&module=teraCPU&auth=auth_name'
An error has occurred while serving metrics:
3 error(s) occurred:
- collected metric "teraSlotIndex" { label:{name:"teraSlotIndex" value:"0"} gauge:{value:0}} was collected before with the same name and label values
- collected metric "teraSlotVersion" { label:{name:"teraSlotIndex" value:"0"} label:{name:"teraSlotVersion" value:"MATL048 CPU 1 F04.04 24.08.23"} gauge:{value:1}} was collected before with the same name and label values
- collected metric "teraSlotStatus" { label:{name:"teraSlotIndex" value:"0"} gauge:{value:15}} was collected before with the same name and label values
tcpdump:
tcpdump: verbose output suppressed, use -v[v]... for full protocol decode listening on lo, link-type EN10MB (Ethernet), snapshot length 262144 bytes 13:18:07.724989 IP 127.0.0.1.9116 > 127.0.0.1.40292: Flags [P.], seq 622047696:622048457, ack 2587925740, win 9206, options [nop,nop,TS val 3601000456 ecr 3600995852], length 761 E..-w4@.@...........#..d%....@....#.."..... ........HTTP/1.1 500 Internal Server Error Content-Type: text/plain; charset=utf-8 X-Content-Type-Options: nosniff Date: Mon, 05 Feb 2024 11:18:07 GMT Content-Length: 591
An error has occurred while serving metrics:
3 error(s) occurred:
- collected metric "teraSlotVersion" { label:{name:"teraSlotIndex" value:"0"} label:{name:"teraSlotVersion" value:"MATL048 CPU 1 F04.04 24.08.23"} gauge:{value:1}} was collected before with the same name and label values
- collected metric "teraSlotStatus" { label:{name:"teraSlotIndex" value:"0"} gauge:{value:15}} was collected before with the same name and label values
- collected metric "teraSlotIndex" { label:{name:"teraSlotIndex" value:"0"} gauge:{value:0}} was collected before with the same name and label values