openfoam-adapter
openfoam-adapter copied to clipboard
Insonsistent data naming scheme across modules
Stemming from https://github.com/precice/openfoam-adapter/pull/197#discussion_r724973150. Check the adapter documentation.
Currently expected name prefixes:
- CHT
-
Temperature
-
Heat-Flux
(snake-case
) -
Sink-Temperature
-
Heat-Transfer-Coefficient
-
- FSI
-
Force
-
Stress
-
Displacement
-
DisplacementDelta
(CamelCase
)
-
- FF (currently not documented :see_no_evil:)
-
Pressure
-
PressureGradient
(CamelCase
) -
Velocity
-
VelocityGradient
-
This would be a breaking change (we would need to update the tutorials), so I would suggest that we choose one system and support both styles until v2.
In the contributing guidelines of preCICE we have already chosen the snake-case
format. This would also be consistent with our precice-config.xml
.
@DavidSCN what do you think?
In the contributing guidelines of preCICE we have already chosen the snake-case format. This would also be consistent with our precice-config.xml.
Sounds good :+1: