VectorAudio icon indicating copy to clipboard operation
VectorAudio copied to clipboard

Unable to transmit when connected to an _1_ position

Open neilenns opened this issue 3 months ago • 7 comments

To reproduce:

  1. Have someone already connected to a position, e.g. PDX_TWR, in CRC
  2. Connect to the same position in CRC with a plan to relieve the other controller
  3. Activate your session in CRC, you'll be connected as PDX_1_TWR
  4. Connect in VectorAudio

Result: You'll connect, but your audio will never transmit out to pilots even though the TX indicator will light up Expected result: Audio transmits fine

It appears to be specific to having _1_ in the callsign. If you wait to connect in CRC until after the other controller disconnects (so you connect as PDX_TWR) everything works fine

neilenns avatar Mar 29 '24 16:03 neilenns

Thank you for the report, it’s not the only report i’ve had on something similar, I will look into it.

On Fri, 29 Mar 2024 at 12:27, Neil Enns @.***> wrote:

To reproduce:

  1. Have someone already connected to a position, e.g. PDX_TWR, in CRC
  2. Connect to the same position in CRC with a plan to relieve the other controller
  3. Activate your session in CRC, you'll be connected as PDX_1_TWR
  4. Connect in VectorAudio

Result: You'll connect, but your audio will never transmit out to pilots even though the TX indicator will light up Expected result: Audio transmits fine

It appears to be specific to having 1 in the callsign. If you wait to connect in CRC until after the other controller disconnects (so you connect as PDX_TWR) everything works fine

— Reply to this email directly, view it on GitHub https://github.com/pierr3/VectorAudio/issues/109, or unsubscribe https://github.com/notifications/unsubscribe-auth/AAN7UK4RJDJZFUGBTYSTPC3Y2WJAPAVCNFSM6AAAAABFOUK5AGVHI2DSMVQWIX3LMV43ASLTON2WKOZSGIYTKNRVGUZTKNA . You are receiving this because you are subscribed to this thread.Message ID: @.***>

pierr3 avatar Mar 29 '24 16:03 pierr3

I've had success fixing this by Forcing a refresh of the audio station in VectorAudio.

DhruvK1985 avatar Apr 04 '24 04:04 DhruvK1985

I've had success fixing this by Forcing a refresh of the audio station in VectorAudio.

How do you do that?

neilenns avatar Apr 06 '24 21:04 neilenns

Click on the box with station name and select “Force refresh”

DhruvK1985 avatar Apr 06 '24 22:04 DhruvK1985

Click on the box with station name and select “Force refresh”

I had no idea that menu was there. Thanks!

neilenns avatar Apr 06 '24 22:04 neilenns

The "Force refresh" method unfortunately doesn't work for me. To work around the issue I do this:

  1. Connect as a _1 position
  2. Wait for the other person to disconnect
  3. Right click on the position in vector audio and delete it
  4. Re-add the position

neilenns avatar Apr 11 '24 12:04 neilenns

When this situation occurs, just manually add your station, for example PDX_TWR and use that to transmit, everything should work as intended. The only issue is that VectorAudio does not consider 1 to be a relief callsign, it only looks at double underscores.

pierr3 avatar Apr 15 '24 05:04 pierr3

This was fixed in TrackAudio, please head over to that repo for this

pierr3 avatar Apr 29 '24 03:04 pierr3