Unable to transmit when connected to an _1_ position
To reproduce:
- Have someone already connected to a position, e.g.
PDX_TWR
, in CRC - Connect to the same position in CRC with a plan to relieve the other controller
- Activate your session in CRC, you'll be connected as
PDX_1_TWR
- Connect in VectorAudio
Result: You'll connect, but your audio will never transmit out to pilots even though the TX
indicator will light up
Expected result: Audio transmits fine
It appears to be specific to having _1_
in the callsign. If you wait to connect in CRC until after the other controller disconnects (so you connect as PDX_TWR
) everything works fine
Thank you for the report, it’s not the only report i’ve had on something similar, I will look into it.
On Fri, 29 Mar 2024 at 12:27, Neil Enns @.***> wrote:
To reproduce:
- Have someone already connected to a position, e.g. PDX_TWR, in CRC
- Connect to the same position in CRC with a plan to relieve the other controller
- Activate your session in CRC, you'll be connected as PDX_1_TWR
- Connect in VectorAudio
Result: You'll connect, but your audio will never transmit out to pilots even though the TX indicator will light up Expected result: Audio transmits fine
It appears to be specific to having 1 in the callsign. If you wait to connect in CRC until after the other controller disconnects (so you connect as PDX_TWR) everything works fine
— Reply to this email directly, view it on GitHub https://github.com/pierr3/VectorAudio/issues/109, or unsubscribe https://github.com/notifications/unsubscribe-auth/AAN7UK4RJDJZFUGBTYSTPC3Y2WJAPAVCNFSM6AAAAABFOUK5AGVHI2DSMVQWIX3LMV43ASLTON2WKOZSGIYTKNRVGUZTKNA . You are receiving this because you are subscribed to this thread.Message ID: @.***>
I've had success fixing this by Forcing a refresh of the audio station in VectorAudio.
I've had success fixing this by Forcing a refresh of the audio station in VectorAudio.
How do you do that?
Click on the box with station name and select “Force refresh”
Click on the box with station name and select “Force refresh”
I had no idea that menu was there. Thanks!
The "Force refresh" method unfortunately doesn't work for me. To work around the issue I do this:
- Connect as a _1 position
- Wait for the other person to disconnect
- Right click on the position in vector audio and delete it
- Re-add the position
When this situation occurs, just manually add your station, for example PDX_TWR
and use that to transmit, everything should work as intended. The only issue is that VectorAudio does not consider 1 to be a relief callsign, it only looks at double underscores.
This was fixed in TrackAudio, please head over to that repo for this