freeds icon indicating copy to clipboard operation
freeds copied to clipboard

Measurement data reception error

Open rmgbp opened this issue 1 year ago • 1 comments

Good evening, I have a problem with my FreeDS. I've been using it for 1 year and until last month without any problems with the Shelly EM data source. Now my data source is a Huawei inverter with battery Luna2000 and the configuration is: Modbus Port :502 Meter Id:1 Error wait time (ms):20000 Data acquisition time (ms):1500 and it is constantly in error: "Measurement data reception error". It stop running a lot of times. Thanks.

rmgbp avatar Oct 07 '24 00:10 rmgbp

Si estas usando huawei debes fijar la adquisición de datos a una velocidad de 150 o 200ms, ya que la lectura se realiza en varios registros consecutivos en lugar de obtenerlos todos en cada petición como se hace con Shelly.

pablozg avatar Oct 20 '24 16:10 pablozg