ThinQ APIv2 error while executing automation
Describe the bug Automation fails when executing: I have an automation that turns the airco/heating on when the temp passes a certain threshold. It sometimes, not always, fails to execute properly, and the automation comes to a halt.
Expected behavior No error, automation succeeds.
Screenshots If applicable, add screenshots to help explain your problem.
Environment details:
- Environment (HASSIO, Raspbian, etc): HAOS 11.2
- Home Assistant version installed: 2023.12.4
- Component version installed: 0.35.6
- Last know working version: ?
- LG device type and model with issue: AC LG-PC18ST
- LG devices connected (list): LG-PC18ST
Output of HA logs Paste the relevant output of the HA log here.
Logger: homeassistant.components.automation.airco_verwarming_aan
Source: helpers/script.py:468
Integration: Automatisering ([documentation](https://www.home-assistant.io/integrations/automation), [issues](https://github.com/home-assistant/core/issues?q=is%3Aissue+is%3Aopen+label%3A%22integration%3A+automation%22))
First occurred: 11:32:03 (1 occurrences)
Last logged: 11:32:03
Airco verwarming aan: Error executing script. Unexpected error for device at pos 1: ThinQ APIv2 error
Traceback (most recent call last):
File "/usr/src/homeassistant/homeassistant/helpers/script.py", line 468, in _async_step
await getattr(self, handler)()
File "/usr/src/homeassistant/homeassistant/helpers/script.py", line 720, in _async_device_step
await device_action.async_call_action_from_config(
File "/usr/src/homeassistant/homeassistant/components/device_automation/action.py", line 71, in async_call_action_from_config
await platform.async_call_action_from_config(hass, config, variables, context)
File "/usr/src/homeassistant/homeassistant/components/climate/device_action.py", line 97, in async_call_action_from_config
await hass.services.async_call(
File "/usr/src/homeassistant/homeassistant/core.py", line 2067, in async_call
response_data = await coro
^^^^^^^^^^
File "/usr/src/homeassistant/homeassistant/core.py", line 2104, in _execute_service
return await target(service_call)
^^^^^^^^^^^^^^^^^^^^^^^^^^
File "/usr/src/homeassistant/homeassistant/helpers/entity_component.py", line 272, in handle_service
return await service.entity_service_call(
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
File "/usr/src/homeassistant/homeassistant/helpers/service.py", line 878, in entity_service_call
single_response = await _handle_entity_call(
^^^^^^^^^^^^^^^^^^^^^^^^^^
File "/usr/src/homeassistant/homeassistant/helpers/service.py", line 948, in _handle_entity_call
result = await task
^^^^^^^^^^
File "/config/custom_components/smartthinq_sensors/climate.py", line 303, in async_set_hvac_mode
await self._device.set_op_mode(operation_mode)
File "/config/custom_components/smartthinq_sensors/wideq/devices/ac.py", line 687, in set_op_mode
await self.set(keys[0], keys[1], key=keys[2], value=mode_value)
File "/config/custom_components/smartthinq_sensors/wideq/devices/ac.py", line 891, in set
await super().set(
File "/config/custom_components/smartthinq_sensors/wideq/device.py", line 569, in set
await self._set_control(
File "/config/custom_components/smartthinq_sensors/wideq/device.py", line 530, in _set_control
await self._client.session.device_v2_controls(
File "/config/custom_components/smartthinq_sensors/wideq/core_async.py", line 1193, in device_v2_controls
res = await self.post2(cmd_path, payload)
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
File "/config/custom_components/smartthinq_sensors/wideq/core_async.py", line 1030, in post2
return await self._auth.gateway.core.lgedm2_post(
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
File "/config/custom_components/smartthinq_sensors/wideq/core_async.py", line 347, in lgedm2_post
return self._manage_lge_result(out, is_api_v2)
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
File "/config/custom_components/smartthinq_sensors/wideq/core_async.py", line 359, in _manage_lge_result
raise API2_ERRORS[code](message)
custom_components.smartthinq_sensors.wideq.core_exceptions.NotLoggedInError: ThinQ APIv2 error
and
Logger: homeassistant.components.automation.airco_verwarming_aan
Source: components/automation/__init__.py:655
Integration: Automatisering ([documentation](https://www.home-assistant.io/integrations/automation), [issues](https://github.com/home-assistant/core/issues?q=is%3Aissue+is%3Aopen+label%3A%22integration%3A+automation%22))
First occurred: 11:32:03 (1 occurrences)
Last logged: 11:32:03
While executing automation automation.airco_verwarming_aan
Traceback (most recent call last):
File "/usr/src/homeassistant/homeassistant/components/automation/__init__.py", line 655, in async_trigger
await self.action_script.async_run(
File "/usr/src/homeassistant/homeassistant/helpers/script.py", line 1578, in async_run
return await asyncio.shield(run.async_run())
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
File "/usr/src/homeassistant/homeassistant/helpers/script.py", line 420, in async_run
await self._async_step(log_exceptions=False)
File "/usr/src/homeassistant/homeassistant/helpers/script.py", line 470, in _async_step
self._handle_exception(
File "/usr/src/homeassistant/homeassistant/helpers/script.py", line 493, in _handle_exception
raise exception
File "/usr/src/homeassistant/homeassistant/helpers/script.py", line 468, in _async_step
await getattr(self, handler)()
File "/usr/src/homeassistant/homeassistant/helpers/script.py", line 720, in _async_device_step
await device_action.async_call_action_from_config(
File "/usr/src/homeassistant/homeassistant/components/device_automation/action.py", line 71, in async_call_action_from_config
await platform.async_call_action_from_config(hass, config, variables, context)
File "/usr/src/homeassistant/homeassistant/components/climate/device_action.py", line 97, in async_call_action_from_config
await hass.services.async_call(
File "/usr/src/homeassistant/homeassistant/core.py", line 2067, in async_call
response_data = await coro
^^^^^^^^^^
File "/usr/src/homeassistant/homeassistant/core.py", line 2104, in _execute_service
return await target(service_call)
^^^^^^^^^^^^^^^^^^^^^^^^^^
File "/usr/src/homeassistant/homeassistant/helpers/entity_component.py", line 272, in handle_service
return await service.entity_service_call(
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
File "/usr/src/homeassistant/homeassistant/helpers/service.py", line 878, in entity_service_call
single_response = await _handle_entity_call(
^^^^^^^^^^^^^^^^^^^^^^^^^^
File "/usr/src/homeassistant/homeassistant/helpers/service.py", line 948, in _handle_entity_call
result = await task
^^^^^^^^^^
File "/config/custom_components/smartthinq_sensors/climate.py", line 303, in async_set_hvac_mode
await self._device.set_op_mode(operation_mode)
File "/config/custom_components/smartthinq_sensors/wideq/devices/ac.py", line 687, in set_op_mode
await self.set(keys[0], keys[1], key=keys[2], value=mode_value)
File "/config/custom_components/smartthinq_sensors/wideq/devices/ac.py", line 891, in set
await super().set(
File "/config/custom_components/smartthinq_sensors/wideq/device.py", line 569, in set
await self._set_control(
File "/config/custom_components/smartthinq_sensors/wideq/device.py", line 530, in _set_control
await self._client.session.device_v2_controls(
File "/config/custom_components/smartthinq_sensors/wideq/core_async.py", line 1193, in device_v2_controls
res = await self.post2(cmd_path, payload)
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
File "/config/custom_components/smartthinq_sensors/wideq/core_async.py", line 1030, in post2
return await self._auth.gateway.core.lgedm2_post(
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
File "/config/custom_components/smartthinq_sensors/wideq/core_async.py", line 347, in lgedm2_post
return self._manage_lge_result(out, is_api_v2)
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
File "/config/custom_components/smartthinq_sensors/wideq/core_async.py", line 359, in _manage_lge_result
raise API2_ERRORS[code](message)
custom_components.smartthinq_sensors.wideq.core_exceptions.NotLoggedInError: ThinQ APIv2 error
Additional context Whenever the automation fails with the APIv2 error, it stops the automation. It stops at when starting the AC, and in the logs it looks like it failed, but the AC actually does start up. The fact that the rest of the automation fails results in the AC heating the room way too high.
config_entry-smartthinq_sensors-67c0cbd9556f496997e9b88ea7938035.json.txt
Exact same issue here.
This issue is stale because it has been open 45 days with no activity. Remove stale label or comment or this will be closed in 7 days.
!
This issue is stale because it has been open 45 days with no activity. Remove stale label or comment or this will be closed in 7 days.
This issue was closed because it has been stalled for 7 days with no activity.