sofie-mos-connection
sofie-mos-connection copied to clipboard
Bug Report: objID strings are incorrectly converted to number
About me
This bug report is posted on behalf of the BBC
Observed Behavior
When ingesting a rundown with MOS objID's that look like numbers sofie-mos-connection
incorrectly converts them to a number
type.
E.G:
100.543210
becomes 100.54321
I'm guessing that this is caused by the nativeType: true
option for the parser, I'm not sure what impact changing it would have...
https://github.com/nrkno/sofie-mos-connection/blob/a87681fed13d3379c41c78cd487606aabbf48128/packages/helper/src/utils/Utils.ts#L13
Expected Behavior
Data from a MOS device should remain of a valid type.
Version
release51
Severity / Impact
~~This is a significant blocker for us as our clip objIDs are numeric as above.~~ A workaround has been implemented so this is less urgent but still an issue.
Thank you for this bug report! We've had a little discussion on this in the Sofie team and we agree that this is an issue in the mos-connection library. We're not actively looking into this issue at the moment, as we haven't experienced the issues ourselves at NRK.
However, we'd welcome any PR to fix this issue and would happily coordinate or collaborate in making a fix.
PR has been made for this fix: https://github.com/nrkno/sofie-mos-connection/pull/101
This should now be resolved as of version v4.2.0-alpha.1