Cyberpower UT850EG is working although it is not listed in the compatibility list
Hi,
I just wanted to let you know that Cyberpower UT850EG is working, although it is not listed in the compatibility list.
I am using WinUSB driver installed with zadig on Windows 10 Pro, and NUT binaries are obtained from NUT-for-Windows-x86_64-RELEASE-2.8.4.7z
UPS information : https://www.cyberpower.com/au/en/product/sku/ut850eg
UPS.conf, running with usbhid-ups -a cyberpower
[cyberpower]
driver = usbhid-ups
port = auto
vendorid = 0764
productid = 0501
Here is the upsc output.
c:\ups\bin>upsc [email protected]
battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 20
battery.mfr.date: CPS
battery.runtime: 1527
battery.runtime.low: 300
battery.status: 100%
battery.type: PbAcid
battery.voltage: 13.7
battery.voltage.nominal: 12
device.mfr: CPS
device.model: UT850EG
device.serial:
device.type: ups
driver.debug: 0
driver.flag.allow_killpower: 0
driver.name: usbhid-ups
driver.parameter.interrupt_pipe_no_events_tolerance: -1
driver.parameter.pollfreq: 12
driver.parameter.pollinterval: 2
driver.parameter.port: auto
driver.parameter.productid: 0501
driver.parameter.synchronous: auto
driver.parameter.vendorid: 0764
driver.state: quiet
driver.version: 2.8.4
driver.version.data: CyberPower HID 0.84
driver.version.internal: 0.67
driver.version.usb: libusb-1.0.27 (API: 0x0100010A)
input.frequency: 50.0
input.transfer.high: 295
input.transfer.low: 167
input.voltage: 244.0
input.voltage.nominal: 230
output.voltage: 243.0
unmapped.ups.powersummary.capacitygranularity1: 5
unmapped.ups.powersummary.capacitygranularity2: 10
unmapped.ups.powersummary.capacitymode: 2
unmapped.ups.powersummary.designcapacity: 100
unmapped.ups.powersummary.rechargeable: 1
ups.beeper.status: enabled
ups.delay.shutdown: 60
ups.delay.start: 120
ups.firmware: BF01701F9
ups.load: 19
ups.mfr: CPS
ups.model: UT850EG
ups.power.nominal: 0
ups.productid: 0501
ups.realpower.nominal: 425
ups.serial:
ups.status: OL
ups.test.result: No test initiated
ups.timer.shutdown: -60
ups.timer.start: -60
ups.vendorid: 0764
This is how it is displayed on HomeAssistant with NUT addon.
Great to hear that it (both the Windows build, and the driver in particular) works for you, thanks for reporting!