suzieq
suzieq copied to clipboard
Poller Requires Restart After LLDP Change
Describe the bug
LLDP is not working on an interface. LLDP is then fixed and output is correctly seen in the LLDP output on the devices.
lldp show
doesn't show the new LLDP info until the poller is restarted.
To Reproduce Steps to reproduce the behavior:
- Remove LLDP
- Ensure LLDP info not shown in Suzieq
- Enable LLDP
- See Suzieq
lldp show
- Output is not shown
- Restart poller
- See Suzieq
lldp show
and info is shown
Attach TBC
Expected behavior LLDP is updated automatically.
Screenshots N/A
Additional context N/A
What platform?
Juniper QFX.
I can't seem to reproduce this Rick, with Junos 19.4R1.10, which is the version of vQFX I have. Could you please see if its still present with 0.15.6?
Is this happening in 0.17.2? I can't seem to reproduce this, @rickdonato