Dual MPPT not showing PV2 at all
Good afternoon, I have a Axpert Plus Duo 3000-24 from Voltacon
Using Watchpower I can see and monitor my 2nd array (PV2) and can see it is fully working from both Watchpower and the LCD panel.
However using this I am unable to view/monitory PV2
root@bf6f3302017b:/opt# /opt/inverter-cli/bin/inverter_poller -d -1 Sat Feb 26 12:27:51 2022 INVERTER: Debug set Sat Feb 26 12:27:52 2022 INVERTER: Current CRC: 49 C1 Sat Feb 26 12:27:52 2022 INVERTER: QMOD reply size (5 bytes) Sat Feb 26 12:27:52 2022 INVERTER: QMOD: 5 bytes read: (B Sat Feb 26 12:27:52 2022 INVERTER: QMOD query finished Sat Feb 26 12:27:52 2022 INVERTER: Current CRC: B7 A9 Sat Feb 26 12:27:52 2022 INVERTER: QPIGS reply size (110 bytes) Sat Feb 26 12:27:52 2022 INVERTER: QPIGS: 110 bytes read: (246.5 50.0 230.8 50.0 0115 0049 003 386 27.15 001 100 0016 0000 000.0 00.00 00000 10010000 00 00 00000 110 Sat Feb 26 12:27:52 2022 INVERTER: QPIGS query finished Sat Feb 26 12:27:52 2022 INVERTER: Current CRC: F8 54 Sat Feb 26 12:27:53 2022 INVERTER: QPIRI reply size (102 bytes) Sat Feb 26 12:27:53 2022 INVERTER: QPIRI: 102 bytes read: (230.0 13.0 230.0 50.0 13.0 3000 2400 24.0 23.5 21.0 29.2 27.0 1 20 060 0 1 2 0 11 0 0 00.0 0 1 080 Sat Feb 26 12:27:53 2022 INVERTER: QPIRI query finished Sat Feb 26 12:27:53 2022 INVERTER: Current CRC: B4 DA Sat Feb 26 12:27:53 2022 INVERTER: QPIWS reply size (38 bytes) Sat Feb 26 12:27:53 2022 INVERTER: QPIWS: 38 bytes read: (0000000000000000010000000000000000 Sat Feb 26 12:27:53 2022 INVERTER: QPIWS query finished INVERTER: ampfactor from config is 1.00 INVERTER: wattfactor from config is 1.01 { "Inverter_mode":4, "AC_grid_voltage":246.5, "AC_grid_frequency":50.0, "AC_out_voltage":230.8, "AC_out_frequency":50.0, "PV_in_voltage":0.0, "PV_in_current":0.0, "PV_in_watts":0.0, "PV_in_watthour":0.0000, "SCC_voltage":0.0000, "Load_pct":3, "Load_watt":49, "Load_watthour":1.6333, "Load_va":115, "Bus_voltage":386, "Heatsink_temperature":16, "Battery_capacity":100, "Battery_voltage":27.15, "Battery_charge_current":1, "Battery_discharge_current":0, "Load_status_on":1, "SCC_charge_on":0, "AC_charge_on":0, "Battery_recharge_voltage":23.5, "Battery_under_voltage":21.0, "Battery_bulk_voltage":29.2, "Battery_float_voltage":27.0, "Max_grid_charge_current":20, "Max_charge_current":60, "Out_source_priority":1, "Charger_source_priority":2, "Battery_redischarge_voltage":2512665466838125624666875924316160.0, "Warnings":"0000000000000000010000000000000000" } Sat Feb 26 12:27:53 2022 INVERTER: All queries complete, exiting loop.
In the above I disconnected PV1 - since it will pick up and monitor PV1 without issue and it certainly doesn't pick up PV2.
For ref my invertor.conf below
device=/dev/hidraw0 run_interval=120 amperage_factor=1.0 watt_factor=1.01 qpiri=102 qpiws=38 qmod=5 qpigs=110
MQQT.json below
"server": "xxx.xxx.xxx.xxx",
"port": "1883",
"topic": "solar",
"devicename": "voltronic",
"username": "user",
"password": "xxxxxxxxx",
"clientid": "voltronic_bd8041d0cdf131a6ba4e5b3360b8bc5a",
"influx": {
"enabled": "false",
"host": "http://xxx.xxx.xxx.xxx:8086",
"username": "user",
"password": "xxxxxxxxxx",
"device": "voltronic",
"prefix": "solar",
"database": "solar",
"namingMap": {
"Inverter_mode": "output_mode",
"AC_grid_voltage": "grid_voltage",
"AC_grid_frequency": "grid_frecuency",
"AC_out_voltage": "ac_output_voltage",
"AC_out_frequency": "ac_output_frecuency",
"PV_in_voltage": "pv_input_voltage_1",
"PV_in_current": "pv_input_current_for_battery",
"PV_in_watts": "pv_input_watts",
"PV_in_watthour": "pv_input_watthour",
"SCC_voltage": "battery_voltage_from_scc",
"Load_pct": "output_load_percent",
"Load_watt": "output_load_watt",
"Load_watthour": "outpu_load_watthour",
"Load_va": "ac_output_power_va",
"Bus_voltage": "bus_voltage",
"Heatsink_temperature": "inverter_heat_sink_temperature",
"Battery_capacity": "battery_capacity",
"Battery_voltage": "battery_voltage",
"Battery_charge_current": "battery_charging_current",
"Battery_discharge_current": "battery_discharge_current",
"Load_status_on": "load_status_on",
"SCC_charge_on": "scc_charge_on",
"AC_charge_on": "ac_charge_on",
"Battery_recharge_voltage": "battery_recharge_voltage",
"Battery_under_voltage": "battery_under_voltage",
"Battery_bulk_voltage": "battery_bulk_voltage",
"Battery_float_voltage": "battery_float_voltage",
"Max_grid_charge_current": "max_grid_charge_current",
"Max_charge_current": "max_charge_current",
"Out_source_priority": "output_source_priority",
"Charger_source_priority": "charger_source_priority",
"Battery_redischarge_voltage": "battery_re_discharge_voltage"
}
}
}
Version information
Main CPU Version 00018.21 SCC1 CPU Version 00000.00 SCC2 CPU Version 00003.28
I've disconnected my PV1 array, below is a screenshot from Watchpower showing PV2
While I know most people will have a single MPPT controller - has anyone any ideas on how to resolve this? Any help appreciated please.
Regards,
Pete
Did you have any joy with this? I will need it when I add something to my pv2, I'm not actually getting PV1 in watts at the moment but get voltage and amps, it might be as easy as changing the PV_in_watts to PV1_in_watts and PV2_in_watts
Hi Darzl,
No, got nowhere with it. I do get both feeds on Watchpower just not anywhere else, I've tried a few things so far all to no avail. That won't stop me looking and trying to work out how Watchpower sees it and yet this doesn't Perhaps it's just me. I will in all likelihood decompile the java into it's components and find out why, it's just a matter of time - which is never on my side.
I switched to https://github.com/catalinbordan/docker-voltronic-homeassistant and now I get my PV power as PV_Charging_Power1 in watts, probably only need to add another line PV_Charging_Power2 or something similar
Thanks I'll take a look.
Regards
This is a little bit old but I added support for a second mppt and created a PR to the repo above. https://github.com/catalinbordan/docker-voltronic-homeassistant/pull/2. The changes are in my fork in case anyone is interested https://github.com/saschalenz/docker-voltronic-homeassistant