foxess_modbus
foxess_modbus copied to clipboard
FoxESS inverter integration. Connect directly to your FoxESS inverter (no cloud!) for real-time status and control.
Step 1 - wired into modbus using an ethernet cable 1 twisted pair (pin 3 and 4) Step 2 - wired into modbus to ethernet adapter connecting relevant cables to...
the latest H3 Pro firmware Master 1.53, Manager 1.22 has flipped the endian for this register; which now matches the Fox modbus definition (V1.05.00.00) see https://github.com/nathanmarlor/foxess_modbus/discussions/685#discussioncomment-10811413
Hi, i have a FoxEss H3 Pro 15kW and use Homeassist and your Plugin since the PV was installed in August. Everything (that I can overview) works great - thanks...
KH inverters upgraded to manager 1.33 and now seeing the following error in HA: Error connecting to inverter (friendly name: "KHM"). Error reading registers. Type: RegisterType.HOLDING; start: 31039; count: 10;...
It does rather look like it doesn't like the registers between37633 and 37700 being read... Maybe we should add those to the disallowed registers list and try again? _Originally posted...
_Originally posted by @matthew270492 in https://github.com/nathanmarlor/foxess_modbus/discussions/686#discussioncomment-10824086_
This might be a bit tricky to implement... But: 1. If we fail to read a batch containing a register, mark them all as "maybe bad" 2. If we fail...
I did a quick EPS test, and I think EPS Power is in holding register 39217 (and possibly 39216 if it's a 32-bit value - which would make the H1_G2...