ha-must-inverter
ha-must-inverter copied to clipboard
unable to connect to Inverter using TCP (WiFi-RS485)
System Health details
System Information
version | core-2024.9.3 |
---|---|
installation_type | Home Assistant OS |
dev | false |
hassio | true |
docker | true |
user | root |
virtualenv | false |
python_version | 3.12.4 |
os_name | Linux |
os_version | 6.6.46-haos |
arch | x86_64 |
timezone | Europe/Kyiv |
config_dir | /config |
Home Assistant Community Store
GitHub API | ok |
---|---|
GitHub Content | ok |
GitHub Web | ok |
HACS Data | ok |
GitHub API Calls Remaining | 5000 |
Installed Version | 2.0.1 |
Stage | running |
Available Repositories | 1422 |
Downloaded Repositories | 2 |
Home Assistant Cloud
logged_in | false |
---|---|
can_reach_cert_server | ok |
can_reach_cloud_auth | ok |
can_reach_cloud | ok |
Home Assistant Supervisor
host_os | Home Assistant OS 13.1 |
---|---|
update_channel | stable |
supervisor_version | supervisor-2024.09.1 |
agent_version | 1.6.0 |
docker_version | 26.1.4 |
disk_total | 30.8 GB |
disk_used | 4.5 GB |
healthy | true |
supported | true |
host_connectivity | true |
supervisor_connectivity | true |
ntp_synchronized | true |
virtualization | kvm |
board | ova |
supervisor_api | ok |
version_api | ok |
installed_addons | Get HACS (1.3.1) |
Dashboards
dashboards | 2 |
---|---|
resources | 0 |
views | 1 |
mode | storage |
Recorder
oldest_recorder_run | 18 вересня 2024 р. о 20:07 |
---|---|
current_recorder_run | 28 вересня 2024 р. о 16:21 |
estimated_db_size | 20.15 MiB |
database_engine | sqlite |
database_version | 3.45.3 |
Checklist
- [X] I have enabled debug logging for my installation.
- [X] I have filled out the issue template to the best of my ability.
- [X] This issue only contains 1 issue (if you have multiple issues, open one issue for each issue).
- [X] This issue is not a duplicate issue of any previous issues..
Describe the issue
Beforehand thanks for Your work!!! :)
I have invertor Must PV18-3224 that I want to monitor with HA. HA and Invertor are on some distance from each other so I can't connect it directly by USB Serial cable. To connect to Invertor remotely I use handmade WiFi-to-Serial adaptor (ESP-01 + esp-link software on it + rs485-to-UART adaptor). I can use SolarPowerMonitor (origin software from Must) and HW Virtual Serial Port software, on PC where SolarMonitor installed, to connect to my ESP and monitor Invertor.
So, my handmade adaptor shouldn't be the issue because origin soft SolarPowerMonitor is working fine.
I added Must Plugin to HA. When I try to add Invertor device by TCP (use IP of ESP) that doesn't work.
My handmade WiFi-to-Serial like the one you used before (on DIN rail) in your post
On the ESP (esp-link software) I can see some Debug. When using Virtual Serial Port and origin Solar Monitor I see in log that soft make one connection (suppose 19200 baud) then close it. After that make one new connection and communicate through it all time.
Your HA Must plugin makes 5 connections and didn't close them. And Esp-link soft can't make more simultaneous connections.
Reproduction steps
- Connect WiFi-to-Serial to Must Invertor
- Add Invrtor device by TCP option into HA Must plugin
- Doesn't add any devices
- Using the same TCP info for connecting origin software Solar Power Monitor thiough Virtual Serial Port works fine ...
Debug logs
From HA log:
2024-09-28 17:21:34.991 ERROR (MainThread) [custom_components.must_inverter] error reading modbus data at address 15201: Exception Response(166, 38, None)
2024-09-28 17:21:42.996 ERROR (MainThread) [custom_components.must_inverter] error reading modbus data at address 20000
Traceback (most recent call last):
File "/config/custom_components/must_inverter/__init__.py", line 239, in read_modbus_data
response = await self._client.read_holding_registers(address=start, count=count, slave=0x04)
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
File "/usr/local/lib/python3.12/site-packages/pymodbus/client/base.py", line 175, in async_execute
raise ModbusIOException(
pymodbus.exceptions.ModbusIOException: Modbus Error: [Input/Output] ERROR: No response received after 3 retries
2024-09-28 17:21:46.010 ERROR (MainThread) [custom_components.must_inverter] error reading modbus data at address 20101
Traceback (most recent call last):
File "/config/custom_components/must_inverter/__init__.py", line 239, in read_modbus_data
response = await self._client.read_holding_registers(address=start, count=count, slave=0x04)
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
File "/usr/local/lib/python3.12/site-packages/pymodbus/client/base.py", line 167, in async_execute
resp = await asyncio.wait_for(
^^^^^^^^^^^^^^^^^^^^^^^
File "/usr/local/lib/python3.12/asyncio/tasks.py", line 520, in wait_for
return await fut
^^^^^^^^^
pymodbus.exceptions.ConnectionException: Modbus Error: [Connection] Connection lost during request
2024-09-28 17:21:46.013 ERROR (MainThread) [custom_components.must_inverter] error reading modbus data at address 25201
Traceback (most recent call last):
File "/config/custom_components/must_inverter/__init__.py", line 239, in read_modbus_data
response = await self._client.read_holding_registers(address=start, count=count, slave=0x04)
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
File "/usr/local/lib/python3.12/site-packages/pymodbus/client/base.py", line 167, in async_execute
resp = await asyncio.wait_for(
^^^^^^^^^^^^^^^^^^^^^^^
File "/usr/local/lib/python3.12/asyncio/tasks.py", line 520, in wait_for
return await fut
^^^^^^^^^
pymodbus.exceptions.ConnectionException: Modbus Error: [Connection] Connection lost during request
Diagnostics dump
No response