MSL 4.1.0 Regressions - Magnetic.QuasiStatic
The following models fail in result comparison. Tested revision: f9bddf86 (2024-02-16)
Changed models, need reference update after library officer check:
- [x] Modelica.Magnetic.QuasiStatic.FundamentalWave.Examples.BasicMachines.InductionMachines.IMC_Conveyor - Reason: - Updated reference files? see below for all 4 issues
- [x] Modelica.Magnetic.QuasiStatic.FundamentalWave.Examples.BasicMachines.InductionMachines.IMC_Initialize - Reason: - Updated reference files? see below for all 4 issues
- [x] Modelica.Magnetic.QuasiStatic.FundamentalWave.Examples.BasicMachines.InductionMachines.IMC_Transformer - Reason: - Updated reference files? see below for all 4 issues
- [x] Modelica.Magnetic.QuasiStatic.FundamentalWave.Examples.BasicMachines.InductionMachines.IMC_YD - Reason: - Updated reference files? see below for all 4 issues All 4 issues: We decided to exclude imc.stator.zeroInductor.i0 from the comparison, since this is more or less only numerical noise. @GallLeo pls. create new reference results based on new comparisonSignals.
Changed output settings (reference update after library officer check):
-
[X] Modelica.Magnetic.QuasiStatic.FundamentalWave.Examples.BasicMachines.SynchronousMachines.SMEE_Generator - Reason: this is apparently not failing anymore in the test run, nothing to do here - Updated reference files? No
-
[ ] Release notes check: Are all classes mentioned which could lead to result changes in user models?
Useful Links
Current comparison report: https://www.ltx.de/download/MA/Compare_MSL_v4.1.0/comparison_report_overview.html -> Reference result test -> Comparison
Comparison signal definitions: https://github.com/modelica/ModelicaStandardLibrary/tree/master/Modelica/Resources/Reference/Modelica https://github.com/modelica/ModelicaStandardLibrary/tree/master/ModelicaTest/Resources/Reference/ModelicaTest
Reference results: https://github.com/modelica/MAP-LIB_ReferenceResults