ModelicaStandardLibrary
ModelicaStandardLibrary copied to clipboard
Electrical.Batteries.Utilities.PulseSeries
fixes #3901 - thanks for pointing out.
In the actual implementation the pause time between the two series is Tp1 + Tp
: Consequently the documentation is updated in f6b3e1105f92bda7116b2d3c3afa438d9b262e23.
As the many parameters may be confusing I am adding this image above to the documentation.
@ahaumer I wonder if this is intended, or if the pause time between the two pulse series shall be simply Tp
@ahaumer The parameter offset
is actually obsolete, as the two ampitudes can be set independently, however.
@christiankral From the image it is not quite clear to me what Tp2 is referring to exactly.
@christiankral From the image it is not quite clear to me what Tp2 is referring to exactly.
OK then: