Trac2GitHub Transition of Modelica Assocication Projects
Trac2GitHub Transition of Modelica Assocication Projects
**Modified by otter on 18 Sep 2015 10:22 UTC**
**Modified by otter on 18 Sep 2015 10:23 UTC**
**Comment by hansolsson on 25 Apr 2016 10:02 UTC** Replying to [comment:9 otter]: > Let me quickly motivate the MCPI for reduction expressions: > > In the MODRIO ITEA project...
**Comment by dietmarw on 2 Feb 2012 09:17 UTC** Christoph Clauss: Thank you for reporting that. We will check it, that means find out the reasons for these different values.
**Comment by clauss on 6 Jun 2012 07:01 UTC** T_ref is generally set to 300.15 kelvin in Modelica.Electrical.Analog. The reason is that SPICE uses 27 Celsius (300 kelvin) as default...
**Modified by clauss on 6 Jun 2012 07:03 UTC**
**Comment by dietmarw on 6 Jun 2012 09:01 UTC** Fixed in aabf47fa9be790ac66e2cd5ce81b136c3d5b26a5.
**Comment by ahaumer on 8 Jun 2012 07:16 UTC** Please, for now leave it at 300.15 K for backwards compatibility not to break existing user models. As soon as a...
**Comment by dietmarw on 8 Jun 2012 07:43 UTC** Toni, well spotted. I reverted the change in 8d9f01b8b5d8c9a576475ad5123a61287547c74a and will reschedule the ticket to the next Milestone with conversion script...
**Comment by otter on 18 Jul 2013 12:11 UTC** This is not a defect, there are just different opinions about a default reference value in different communities. Therefore changed to...