Michael Mehari

Results 19 comments of Michael Mehari

That is correct, and I noticed it after making the PR.

I have made the change

Or possibly @MatthewSteeves. He seems to have interest.

> @mmehari Awesome work! Do you know if there is a maximum frequency that this supports? Well the maximum frequency supported is related to the range of Signal Gen CH1,...

It is not an unexpected behaviour in the sense of a bug from the calculation, but it is more like a limitation of the applied methodology. In the course of...

Along the way, I found one extra bug. The thing is oscilloscope CH2 UI is disabled in frequency response mode and it was not re-enabled when switching to frequency spectrum...

I have addressed both wishlists and let me know if that is what you have asked

The frequency response calculation requires both Oscilloscopes (CH1 and CH2) to be present and receive samples. Hence it beneficial to make them non checkable. commit https://github.com/espotek-org/Labrador/pull/272/commits/84541a90dde430e92ac3408eaa25d461aec140b0 does this.

Wiki is updated. https://github.com/espotek-org/Labrador/wiki/Frequency-Response-Calculation