Sungrow-SHx-Inverter-Modbus-Home-Assistant icon indicating copy to clipboard operation
Sungrow-SHx-Inverter-Modbus-Home-Assistant copied to clipboard

SG8.0RS Data Missing vs Sungather

Open bullantmm opened this issue 5 months ago • 0 comments

Discussed in https://github.com/mkaiser/Sungrow-SHx-Inverter-Modbus-Home-Assistant/discussions/334

Originally posted by **bullantmm** September 11, 2024
I have setup this integration to mostly work with my SG8.0RS by going through all modbus registers and setting them correctly in modbus_sungrow.yaml however it seems a few values just won't take. Load Power, Daily exported energy, Daily imported energy are all available via Sungather (https://github.com/bohdan-s/SunGather/tree/main) but I can't seem to make them work in this integration... Any help appreciated.

Here is the output of Sungather: 5000 | device_type_code | SG80RS vr001 | run_state | ON vr003 | last_reset | 2024-9-11 0:00:13 vr006 | daily_export_to_grid | 4.4109833333333315 kWh vr007 | daily_import_from_grid | 11.557683333333342 kWh 4950 | protocol_number | 1095971072 4952 | protocol_version | 16849152 4954 | arm_software_version | 16722 4969 | dsp_software_version | 19780 4990 | serial_number | XXXXXXXXXXX 5001 | nominal_active_power | 8.0 kW 5002 | output_type | 2P 5003 | daily_power_yields | 8.1 kWh 5004 | total_power_yields | 71.7 kWh 5006 | total_running_time | 26 h 5008 | internal_temperature | 44.2 °C 5009 | total_apparent_power | 4559 VA 5011 | mppt_1_voltage | 229.0 V 5012 | mppt_1_current | 6.4 A 5013 | mppt_2_voltage | 230.9 V 5014 | mppt_2_current | 5.6 A 5015 | mppt_3_voltage | 288.2 V 5016 | mppt_3_current | 6.5 A 5017 | total_dc_power | 4677 W 5019 | phase_a_voltage | 241.1 V 5020 | phase_b_voltage | 0.0 V 5021 | phase_c_voltage | 0.0 V 5022 | phase_a_current | 18.8 A 5023 | phase_b_current | 0.0 A 5024 | phase_c_current | 0.0 A 5031 | total_active_power | 4558 W 5033 | total_reactive_power | 462 Var 5035 | power_factor | 1.0 5036 | grid_frequency | 50.0 Hz 5038 | work_state_1 | Dispatch Run 5040 | alarm_time_month | 0 5041 | alarm_time_day | 0 5042 | alarm_time_hour | 0 5043 | alarm_time_minute | 0 5045 | alarm_time_second | 0 5045 | alarm_code_1 | 0 5049 | nominal_reactive_power | 4.8 kVar 5071 | array_insulation_resistance | 1894 k-ohm 5077 | active_power_regulation_setpoint | 8000 W 5079 | reactive_power_regulation_setpoint | 0 Var 5081 | work_state_2 | Run 5083 | meter_power | -3521 W 5085 | meter_a_phase_power | 0 W 5087 | meter_b_phase_power | 0 W 5089 | meter_c_phase_power | 0 W 5091 | load_power | 1037 W 5093 | daily_export_energy | 0.0 kWh 5095 | total_export_energy | 43.3 kWh 5097 | daily_import_energy | 0.0 kWh 5099 | total_import_energy | 69.1 kWh 5101 | daily_direct_energy_consumption | 0.0 kWh 5103 | total_direct_energy_consumption | 0.0 kWh 5113 | daily_running_time | 224 min 5115 | mppt_4_voltage | 0.0 V 5116 | mppt_4_current | 0.0 A 5117 | mppt_5_voltage | 0.0 V 5118 | mppt_5_current | 0.0 A 5119 | mppt_6_voltage | 0.0 V 5120 | mppt_6_current | 0.0 A 5121 | mppt_7_voltage | 0.0 V 5122 | mppt_7_current | 0.0 A 5123 | mppt_8_voltage | 0.0 V 5124 | mppt_8_current | 0.0 A 5128 | monthly_power_yields | 71.7 kWh 5130 | mppt_9_voltage | 0.0 V 5131 | mppt_9_current | 0.0 A 5132 | mppt_10_voltage | 0.0 V 5133 | mppt_10_current | 0.0 A 5134 | mppt_11_voltage | 0.0 V 5135 | mppt_11_current | 0.0 A 5136 | mppt_12_voltage | 0.0 V 5137 | mppt_12_current | 0.0 A 5146 | negative_voltage_to_the_ground | 0.0 V 5147 | bus_voltage | 390.6 V 5150 | pid_work_state | None 5151 | pid_alarm_code | None 5216 | export_power | -3525 W 5218 | power_meter | 1017 W 5601 | meter_total_power | -3521 W 5603 | meter_phase_a_power | 0 W 5605 | meter_phase_b_power | 0 W 5607 | meter_phase_c_power | 0 W 5622 | export_limit_min | 0 W 5623 | export_limit_max | 8000 W 5628 | bdc_rated_power | 0 W 5635 | bms_max_charging_current | 0 A 5636 | bms_max_discharging_current | 0 A 5723 | backup_phase_a_power | 0 W 5724 | backup_phase_b_power | 0 W 5725 | backup_phase_c_power | 0 W 5726 | total_backup_power | 0 W 6386 | direct_power_consumption_pv | 0.0 kWh 7013 | string_1_current | 0.0 A 7014 | string_2_current | 0.0 A 7015 | string_3_current | 0.0 A 7016 | string_4_current | 0.0 A 7017 | string_5_current | 0.0 A 7018 | string_6_current | 0.0 A 7019 | string_7_current | 0.0 A 7020 | string_8_current | 0.0 A 7021 | string_9_current | 0.0 A 7022 | string_10_current | 0.0 A 7023 | string_11_current | 0.0 A 7024 | string_12_current | 0.0 A 7025 | string_13_current | 0.0 A 7026 | string_14_current | 0.0 A 7027 | string_15_current | 0.0 A 7028 | string_16_current | 0.0 A 7029 | string_17_current | 0.0 A 7030 | string_18_current | 0.0 A 7031 | string_19_current | 0.0 A 7032 | string_20_current | 0.0 A 7033 | string_21_current | 0.0 A 7034 | string_22_current | 0.0 A 7035 | string_23_current | 0.0 A 7036 | string_24_current | 0.0 A 5006 | start_stop | Start 5007 | power_limitation_switch | Enable 5008 | power_limitation_setting | 100.0 % 5010 | export_power_limitation | None 5011 | export_power_limitation_value | 0 5012 | current_transformer_output_current | 0 A 5013 | current_transformer_range | 0 A 5014 | current_transformer | None 5015 | export_power_limitation_percentage | 0.0 % 5016 | installed_pv_power | 0.0 KW 5019 | power_factor_setting | 0.0 5035 | night_svg_switch | Disable 5036 | reactive_power_adjustment_mode | Enable Q(U) 5037 | reactive_power_percentage_setting | 0.0 % 5039 | power_limitation_adjustment | 8.0 kW 5040 | reactive_power_adjustment | 0.0 kVar 5041 | pid_recovery | Disable 5042 | anti_pid | None 5043 | fullday_pid_suppression | None 33047 | battery_max_charge_power | 0 W 33048 | battery_max_discharge_power | 0 W vr002 | timestamp | 2024-9-11 10:39:46 vr004 | export_to_grid | 3521 W vr005 | import_from_grid | 0 W

bullantmm avatar Sep 11 '24 00:09 bullantmm