adflow
adflow copied to clipboard
SA-R implementation is incorrect
Description
There are two problems with the SA-R implementation here (the same code also appears in the blockette code) when compared to the TMR website:
- The min function is missing the minus omega in the second argument. As a result, the min always evaluates to zero and SA-R solutions are identical to SA.
- The if statement is checked for both strain and vorticity production, but SA-R is only valid for vorticity production.