wideband
wideband copied to clipboard
Weird behaviour of hand soldered F0 board runing latest firmware
Hello,
I have two f0 boards which have two different behaviours, both running November firmware from mck1137/wideband.
- Nerst voltage fluctuates depening on the applied oxygen (sensor over candle or lighter) afr sometimes jumps if nerst crossed over 450mV
- Nerst voltage stays fixed at around 450mV, pump current changes depending on applied oxygen, AFR stays pretty much fixed at around 15.45
I've attached logs from both boards 2024-01-18_18.02.05.zip
Both boards are hand assembled so there might an issue with soldering??
//EDIT I've verified all solder joints and now both units behave like in the log below, the spikes are nerst V and pump DC are from me applying propane to the sensor 2024-01-18_21.41.24.zip 2024-01-18_18.02.05.zip 2024-01-18_21.41.24.zip
@dynfer please describe your power supply
@dynfer maybe add a photo of the overall setup?
@dynfer please describe your power supply
@dynfer maybe add a photo of the overall setup?
For power I've used a AC/DC 12V 1A power brick and 12v from PC power supply both shared the behaviour
Only thing that would differ from a standard setup that I have soldered wires directly to the pins of the 12pin connector on the carrier board instead of using the connector itself.