Bed_Distance_sensor icon indicating copy to clipboard operation
Bed_Distance_sensor copied to clipboard

Unknown command:"SET_KINEMATIC_POSITION"

Open Billy-d-Kidd opened this issue 1 year ago • 2 comments

Trying to re-calibrate the sensor and I keep getting:

Unknown command:"SET_KINEMATIC_POSITION" Calibrating, don't power off the printer Collision: 0.7200 mm, Bed: 24.1C warning: triggered in air, 744 Homing M102 S-6

I tried 'SET_KINEMATIC_POSITION Z=200' prior to sending M102 S-6 as well, and same result of unknown command.

Billy-d-Kidd avatar May 16 '24 14:05 Billy-d-Kidd

just add this into the printer.cfg

[force_move] 
enable_force_move: true 

markniu avatar May 16 '24 14:05 markniu

just add this into the printer.cfg [force_move] enable_force_move: true

Calibrate Finished! Please Wait... Calibrating, don't power off the printer Collision: 0.7040 mm, Bed: 24.2C warning: triggered in air, 743 Homing M102 S-2

That worked, thanks.

Billy-d-Kidd avatar May 16 '24 14:05 Billy-d-Kidd

Worked for me too. Thanks.

SmittyHalibut avatar Jun 14 '25 18:06 SmittyHalibut