midea-msmart icon indicating copy to clipboard operation
midea-msmart copied to clipboard

Version 3 issue with swing mode and fan speed

Open justanoldman opened this issue 2 years ago • 2 comments

Hi just tried using the latest version for a V3 a/c and the swing mode does not function at all works fine for V2 A/C also the fan speed returns unknown for Full changes the speed ok but does not seem to report status correctly in both V2 and V3 and in V3 all other speeds except High return unknown for status V2 returns fine but V3 seems to return different value ie V2 low returns 40 in debug in V3 low returns 30 in debug same for medium and silent as well

justanoldman avatar May 11 '22 17:05 justanoldman

sorry, I didn't get it. can you redescribe the problem? If you are chinese, you can use chinese.

mac-zhou avatar May 12 '22 07:05 mac-zhou

Hi, The swing mode does not work to turn on or off the swing mode Off Vertical Horizontal Both setting do nothing when sent to a A/C Unit that is version 3 This function works fine for unit that is Version 2 Fan speeds return different Value from V2 A/C and V3 A/C see snippet below commands sent using example.py

Version 2 Target A/C commands sent device.fan_speed = ac.fan_speed_enum.Full device.swing_mode = ac.swing_mode_enum.Both

debug returns DEBUG:msmart.device.AC.appliance:Unknown Fan Speed: 0 {'id': *********, 'name': '192.168.1.51', 'power_state': True, 'prompt_tone': True, 'target_temperature': 24.0, 'operational_mode': <operational_mode_enum.cool: 2>, 'fan_speed': <fan_speed_enum.Auto: 102>, 'swing_mode': <swing_mode_enum.Both: 15>, 'eco_mode': False, 'turbo_mode': False, 'indoor_temperature': 22.0, 'outdoor_temperature': 22.5}

Version 2 Target A/C commands sent device.fan_speed = ac.fan_speed_enum.Low

debug returns DEBUG:msmart.command:Appliance response data: c00148287f7f003f0000005f5f00000000000000000000008c74 {'id': ***************, 'name': '192.168.1.51', 'power_state': True, 'prompt_tone': True, 'target_temperature': 24.0, 'operational_mode': <operational_mode_enum.cool: 2>, 'fan_speed': <fan_speed_enum.Low: 40>, 'swing_mode': <swing_mode_enum.Both: 15>, 'eco_mode': False, 'turbo_mode': False, 'indoor_temperature': 22.0, 'outdoor_temperature': 22.5}

Version 3 Version 3 Target A/C commands sent device.fan_speed = ac.fan_speed_enum.Full device.swing_mode = ac.swing_mode_enum.Both

debug returns DEBUG:msmart.device.AC.appliance:Unknown Fan Speed: 0 {'id': ******, 'name': '192.168.1.99', 'power_state': True, 'prompt_tone': True, 'target_temperature': 24.0, 'operational_mode': <operational_mode_enum.cool: 2>, 'fan_speed': <fan_speed_enum.Auto: 102>, 'swing_mode': <swing_mode_enum.Off: 0>, 'eco_mode': False, 'turbo_mode': False, 'indoor_temperature': 22.0, 'outdoor_temperature': 21.5, }

Version 3 Version 3 Target A/C commands sent device.fan_speed = ac.fan_speed_enum.Low

debug returns DEBUG:msmart.device.AC.appliance:Unknown Fan Speed: 30 {'id': **********, 'name': '192.168.1.99', 'power_state': True, 'prompt_tone': True, 'target_temperature': 24.0, 'operational_mode': <operational_mode_enum.cool: 2>, 'fan_speed': <fan_speed_enum.Auto: 102>, 'swing_mode': <swing_mode_enum.Off: 0>, 'eco_mode': False, 'turbo_mode': False, 'indoor_temperature': 22.0, 'outdoor_temperature': 21.0, }

I can provide full out from both if needed but the above behavior is what I am talking about

justanoldman avatar May 12 '22 12:05 justanoldman