AH-Net icon indicating copy to clipboard operation
AH-Net copied to clipboard

Metrics for TP/FP detection

Open Westerby opened this issue 4 years ago • 1 comments

Hello, in the paper it is mentioned that "true positive finding if the maximal point resides in a 3D bounding box annotated by the radiologist". Do you know if that was dealt with automatically? How were predictions assigned to GT boxes if there were several detections and several bounding boxes?

Thanks.

Westerby avatar Oct 08 '19 10:10 Westerby

Not sure if I understood your question. True positive here means true positive markers that can be catched by a lesion finding annotated by the radiologist (3D bounding box).

There could be multiple detected markers outputted by the nonmaximal suppression in the same volume. The maximal point here means the local maximals. Not the global maximal.

Hope I answered your question.

For a good example to compute the FROC curve, you can check the script from the LUNA challenge:https://luna16.grand-challenge.org/evaluation/

On Tue, Oct 8, 2019, 6:04 AM Westerby [email protected] wrote:

Hello, in the paper it is mentioned that "true positive finding if the maximal point resides in a 3D bounding box annotated by the radiologist". Do you know if that was dealt with automatically? How were predictions assigned to GT boxes if there were several detections and several bounding boxes?

Thanks.

— You are receiving this because you are subscribed to this thread. Reply to this email directly, view it on GitHub https://github.com/lsqshr/AH-Net/issues/3?email_source=notifications&email_token=AAL6ZBJ7LVCDCICBVWGJKXTQNRLLTA5CNFSM4I6PUT5KYY3PNVWWK3TUL52HS4DFUVEXG43VMWVGG33NNVSW45C7NFSM4HQJVPNA, or mute the thread https://github.com/notifications/unsubscribe-auth/AAL6ZBO3PSG7FRTBOKTVEITQNRLLTANCNFSM4I6PUT5A .

lsqshr avatar Oct 08 '19 23:10 lsqshr