If this is a connected session, then the PLC will terminate the connection on its end after some period of inactivity. In my own library, this is set to about...
If you are using my code for examples, I recently added support for listing program tags too. For other examples, please look at D.M Roeder's [pylogix](https://github.com/dmroeder/pylogix). That's where I learned...
Have any notes on how to set up the ForwardOpen for implicit messaging? I'd like to give it a try in my library.
Thanks! I'll take look.
I have had success writing UDTs in my library. I cheat. Before the first write, I make sure I do a read. I copy the type bytes into local memory...
When I implemented Micro800 support in my library, all I had to do was to leave out the path part. It does not take an IOI path that includes the...
Note that implicit data, such as used by produced/consumed tags, uses a form of Forward Open that I have not fully decoded, but then it usually requires multicast UDP support....
De-lurking for a minute. I have a similar library in C, but I thought I would share my experiences here. There are a combination of factors that can impact performance....
Ugh. I left out an important part about connection drops. They only happen if you stop traffic to the PLC for some reason. If you have a continuous flow of...
Here is what I get (I don't have an array of REAL, but I read an array of 1000 DINT twice). The PC is a Dell XPS 13 (2018 model)...