Marlin-2-0-x-Anycubic-Kossel-Linear-Plus
Marlin-2-0-x-Anycubic-Kossel-Linear-Plus copied to clipboard
Kossel Linear Plus
Hi, the firmware for kossel linear plus seems to not be correct..
First issue: when probing, it will fail b/c the probe will not go all the way down. Only way to correct this was to set the z-height of the printer back to its original 300mm - why was that changed to 270 in your firmware anyway? Second: After measuring the probe-height and running the calibration, when I try to print with Cura (4.4), the extruder starts at what looks like a good height to me, then moves up into the air (about 1.5cm) above the printbead and tries to print the first layer there...
Second problem was caused by cura 4.4 as it seems - with RepetierHost I can print as expected.
Can confirm. After flashing, preset height was 270 and after changing it to 280mm (max value), z 0 was at 0.0 again.
I can also confirm this. I had to change the delta height in:
Configuration → Delta Calibration → Delta Settings
to 280mm and store settings. After this, the auto calibration worked.