MCUViewer icon indicating copy to clipboard operation
MCUViewer copied to clipboard

X axis zooming during acquisition

Open dzid26 opened this issue 9 months ago • 3 comments

This viewport range is sample based, but could be time based: image

This is time based but doesn't work image

It's a "nice to have".

dzid26 avatar May 03 '24 13:05 dzid26

Please explain further. I'm not sure what you mean.

klonyyy avatar May 03 '24 17:05 klonyyy

I am referring to viewport X axis [time] range. Currently it can be only globally controlled from Acquisition settings using number of samples.

It would be more powerful if viewport time range was controllable from the plot right click menu - using time units and maybe with the mouse- during acquisition.

  • Currently, I believe, Autofit and min/max [seconds] are ignored on time axis - when acquisition is started.
  • Zooming in and out with the mouse only works during acquisition.

In contrast, for Y axis the range can be changed during acquisition. Although, zooming with the mouse also doesn't.

dzid26 avatar May 03 '24 20:05 dzid26

I think the perfection would be the following:

  • Mouse zooming available for X and Y when stopped and during acquisition.
  • Possibility to adjust Min/max when stopped, and setting not forgotten when acquisition starts, - related to https://github.com/klonyyy/STMViewer/issues/52

Perhaps this would complicate things too much at this moment.

dzid26 avatar May 03 '24 20:05 dzid26

Please reopen/react to this post if you agree this feature is needed. I'm closing for now.

klonyyy avatar Sep 20 '24 19:09 klonyyy