magento2-enhanced-smtp icon indicating copy to clipboard operation
magento2-enhanced-smtp copied to clipboard

Failing Unit Test

Open HenKun opened this issue 5 years ago • 0 comments

Failing unit test due to missing constructor parameter

Preconditions

Magento version 2.3.2 Enhanced SMTP version 1.0.7

Steps to reproduce

Run unit test SaveEmailLogTest::testPrepareMessage()

Expected result

Test passes

Actual result

TypeError : Argument 6 passed to KiwiCommerce\EnhancedSMTP\Email\Log\SaveEmailLog::__construct() must be an instance of Magento\Framework\Mail\MessageInterfaceFactory or null, instance of Mock_LogsFactory_267748ca given

Solution

To overcome the issue, a mock of type \Magento\Framework\Mail\MessageInterfaceFactory should be passed as 6th argument to SaveEmailLog constructor.

However, this leads to a successive failure: Error : Call to a member function create() on null

This is because the constructor of SaveEmailLog decided - based on the Magento version - which parent constructor should be called.

By default it takes the first variant in unit tests, because the real Magento version is not evaluated. So the base class of Magento version < 2.2.8 is used.

Luckily the constructor of the base class in v 2.3.2 is backward compatible and gets the MessageInterfaceFactory itself from the object manager, if null is passed.

But this leads to further problems, I could not further investigate.

HenKun avatar Feb 11 '20 09:02 HenKun