HI
On the latest version, installed this morning (Sunsynk Inverter Add-on (multi): Current version: 2023.04.20b-0.3.2 (Changelog)) I get the below errors as reported in the log. The application then crash. Any ideas on a possible fix and the reason for these?
Thanks
2023-04-21 07:32:39,121 ERROR Read Error: <class 'Exception'>: (1,59,1) 'Serial' object has no attribute 'host' 2023-04-21 07:32:52,742 ERROR Read Error: <class 'Exception'>: (1,268,6) 'Serial' object has no attribute 'host' 2023-04-21 07:33:03,835 ERROR Read Error: <class 'Exception'>: (1,59,1) 'Serial' object has no attribute 'host' 2023-04-21 07:33:18,948 ERROR Read Error: <class 'Exception'>: (1,59,1) 'Serial' object has no attribute 'host' 2023-04-21 07:34:38,121 ERROR Read Error: <class 'Exception'>: (1,78,1) 'Serial' object has no attribute 'host'
@cakuhn can you try these options?
-
pymodbus - Using the device selected in
DEBUG_DEVICE
(at the bottom of the settings)DRIVER: pymodbus INVERTERS: - PORT: ""
-
Direct Serial + pymodbus
DRIVER: pymodbus INVERTERS: - PORT: /dev/serial/by-id/usb-FTDI_FT232R_USB_UART_A9007CPR-if00-port0
-
Direct serial + umodbus
DRIVER: umodbus INVERTERS: - PORT: serial:///dev/serial/by-id/usb-FTDI_FT232R_USB_UART_A9007CPR-if00-port0
-
umodbus via mbusd (and mbusd to serial) This will work, but won't help me to test the serial implementation.
I had the exact same issue after migrating to the new release. I am glad I came across this thread as, touch wood, Direct Serial + pymodbus seemed to have resolved it. I am using a RS485 to usb converter direct to my HA server.
There was a thread on powerforum with a user with the same issue, I will link them here for resolution. Update: See you already responded there.
PS. thanks for your work on this addon!
Same failure on my side since upgrading to HassOS 10.1. I've tried all 3 methods above to no avail.
-
When using Direct Serial + pymodbus I get no errors, but also no sensors available: 2023-05-01 17:01:07,796 INFO ############################################################ 2023-05-01 17:01:07,796 INFO Inverter serial number '2209272082' 2023-05-01 17:01:07,796 INFO ############################################################ 2023-05-01 17:01:07,798 INFO MQTT: Connecting to [email protected]:1883
-
When using Direct serial + umodbus I get similar error as above: 2023-05-01 17:06:40,723 ERROR Read Error: <class 'Exception'>: (1,16,2) 'Serial' object has no attribute 'host' 2023-05-01 17:06:40,744 INFO ############################################################ 2023-05-01 17:06:40,744 INFO No response on the Modbus interface serial:///dev/serial/by-id/usb-Prolific_Technology_Inc._USB-Serial_Controller-if00-port0, try checking the wiring to the Inverter, the USB-to-RS485 converter, etc
Any help would be appreciated. Thnx
- When using Direct Serial + pymodbus I get no errors, but also no sensors available: 2023-05-01 17:01:07,796 INFO ############################################################ 2023-05-01 17:01:07,796 INFO Inverter serial number '2209272082' 2023-05-01 17:01:07,796 INFO ############################################################ 2023-05-01 17:01:07,798 INFO MQTT: Connecting to [email protected]:1883
This is good. You either have no sensors in the addon config, or no auto-discovery enabled in HA
Thnx for responding. I definitely haven't turned off auto-discovery in HA and my addon config lists the following sensors:
- total_pv_energy
- total_battery_charge
- total_battery_discharge
- total_grid_export
- total_grid_import
- battery_soc However on starting the addon with pymodbus, show me: 2023-05-01 20:30:08,423 INFO Filter *last used for battery_soc, total_battery_charge, total_battery_discharge, total_grid_export, total_grid_import, total_pv_energy
I'm not a complete newb, but I must admit, this has had me pulling my hair out the last week! Any help would be appreciated. Thnx
DRIVER: pymodbus INVERTERS: - PORT: ""
Thanks so much, This one worked for me "pymodbus - Using the device selected in DEBUG_DEVICE (at the bottom of the settings)".
All time out errors experienced on the original version is also gone now. Using the NOW sensors, it also updates almost instantly by the second. AWESOMENESS
Thnx for responding. I definitely haven't turned off auto-discovery in HA and my addon config lists the following sensors:
- total_pv_energy
- total_battery_charge
- total_battery_discharge
- total_grid_export
- total_grid_import
- battery_soc However on starting the addon with pymodbus, show me: 2023-05-01 20:30:08,423 INFO Filter *last used for battery_soc, total_battery_charge, total_battery_discharge, total_grid_export, total_grid_import, total_pv_energy
I'm not a complete newb, but I must admit, this has had me pulling my hair out the last week! Any help would be appreciated. Thnx
Best to open your own issue, as the driver seems to only be one of your problems. Please include all detail there including your mqtt server info
Thnx guys. After much struggling, the problem was the connection to the MQTT server! Prior to HassOS 10.1, connecting to HA internal MQTT server on 127.0.0.1 was working fine, but fails for some reason in 10.1. FINALLY working again. Thanks for a great addon!
Thnx guys. After much struggling, the problem was the connection to the MQTT server! Prior to HassOS 10.1, connecting to HA internal MQTT server on 127.0.0.1 was working fine, but fails for some reason in 10.1.
in most cases core-mosquitto (the default) should work fine. 127.0.0.1 is not expected to work in standard Docker, as this points to the addon container itself
FINALLY working again. Thanks for a great addon!
👍🏼
@cakuhn can you try these options?
- pymodbus - Using the device selected in
DEBUG_DEVICE
(at the bottom of the settings)DRIVER: pymodbus INVERTERS: - PORT: ""
- Direct Serial + pymodbus
DRIVER: pymodbus INVERTERS: - PORT: /dev/serial/by-id/usb-FTDI_FT232R_USB_UART_A9007CPR-if00-port0
- Direct serial + umodbus
DRIVER: umodbus INVERTERS: - PORT: serial:///dev/serial/by-id/usb-FTDI_FT232R_USB_UART_A9007CPR-if00-port0
- umodbus via mbusd (and mbusd to serial) This will work, but won't help me to test the serial implementation.
I have a similar issue as reported at the opening of the issue. All pymodbus options give me the following error:
2023-08-15 19:28:56,497 INFO Loading HASS OS configuration
2023-08-15 19:28:56,736 INFO Using Single phase sensor definitions.
2023-08-15 19:28:56,740 INFO Connecting to /dev/serial/by-id/usb-Exar_Corp._XR21B1411_E5019832061-if00
2023-08-15 19:28:56,741 INFO PyModbus 3.2.2 Serial: /dev/serial/by-id/usb-Exar_Corp._XR21B1411_E5019832061-if00
2023-08-15 19:28:56,745 INFO Serial connected.
2023-08-15 19:28:56,747 INFO Connected to /dev/serial/by-id/usb-Exar_Corp._XR21B1411_E5019832061-if00
2023-08-15 19:28:56,747 INFO Reading startup sensors rated_power, serial
2023-08-15 19:28:59,756 INFO Serial lost connection.
2023-08-15 19:28:59,758 INFO Serial lost connection.
2023-08-15 19:28:59,759 WARNING Ignoring launch of delayed reconnection, another is in progress
2023-08-15 19:28:59,766 ERROR timeout reading register 3 (5)
2023-08-15 19:28:59,767 INFO ############################################################
2023-08-15 19:28:59,768 INFO No response on the Modbus interface /dev/serial/by-id/usb-Exar_Corp._XR21B1411_E5019832061-if00, try checking the wiring to the Inverter, the USB-to-RS485 converter, etc
2023-08-15 19:28:59,768 INFO ############################################################
2023-08-15 19:28:59,769 CRITICAL This Add-On will terminate in 30 seconds, use the Supervisor Watchdog to restart automatically.
2023-08-15 19:28:59,869 INFO Serial connected.
2023-08-15 19:28:59,871 INFO Connected to /dev/serial/by-id/usb-Exar_Corp._XR21B1411_E5019832061-if00
The umodbus options gives me the same error: 'Serial' object has no attribute 'host'
The cable should work as I have tested it with a SolarAssitant setup, however, that was on a Deye 5kw inverter. I'm trying to install this add-on on a Sunsynk 8kW,
mbusb
does not seem to connect.
@kellerza Any ideas?
Try the faul finding guide & make sure you plug it into the correct port - see the adaptors & wiring page. Maybe this is a newer model with a shared port?
I've tried both ports to test whether it is a combined port. I've also checked everything on the fault finding page.
As stated previously the cable wiring is definitely correct as it work on a previous SolarAssistant setup. Is there a way to check the port on the Inverter, i.e. that it is actually working.
Try from your laptop with modbuspoll/modbus CLI
If still not working ~R100 will get you a different RS485 adaptor & run a short wire while standing next to the inverter.
Personally, I would just redo the wire since you changed the Inverter
Ok I preserved ( 11hrs solid lol ) . I got a connection after entering the inverter serial number and changing port to “ “. So the log went further than before but stopped at seemingly waiting for mqtt ? So I added mqtt broker and now it works except I’m missing some data like pv2 and total solar ( pv1+pv2 ). How can I add the sensor ? also power flow card doesn’t show data. 09:10:04 INFO Inverter serial number '****6757' 09:10:04 INFO ############################################################ 09:10:04 INFO MQTT: Connecting to Home@core-mosquitto:1883
Then after broker install
09:10:08 INFO MQTT: Connection successful 09:10:08 INFO Read every (inverter 1) +-----+---------------------------------------------------------------------------------+ | s | Sensors | +-----+---------------------------------------------------------------------------------+ | 2 | grid_ct_power, inverter_power, grid_power, pv1_power, battery_power, aux_power, | | | non_essential_power, essential_power | | 5 | prog1_power, prog5_capacity, prog3_charge, prog3_time, prog4_capacity, | | | prog1_time, prog1_charge, prog6_capacity, use_timer, load_limit, prog5_time, | | | prog3_capacity, prog6_power, prog2_time, battery_low_capacity, prog2_capacity, | | | prog4_charge, priority_load, prog5_charge, prog1_capacity, prog2_power, | | | prog6_time, prog5_power, prog2_charge, prog4_power, prog6_charge, prog4_time, | | | prog3_power | | 15 | grid_frequency, overall_state, battery_soc, battery_voltage, grid_voltage, | | | pv1_current, grid_connected, battery_current, inverter_current, pv1_voltage, | | | load_frequency | | 300 | total_grid_import, day_battery_discharge, total_pv_energy, | | | total_battery_discharge, day_battery_charge, total_battery_charge, | | | day_pv_energy, day_grid_export, total_grid_export, day_grid_import, | | | day_load_energy | +-----+---------------------------------------------------------------------------------+ 09:10:09 INFO Report every (inverter 1) +-----+----------------------------------------------------------------------------------+ | s | Sensors | +-----+----------------------------------------------------------------------------------+ | 2 | grid_ct_power, inverter_power, grid_power, pv1_power, battery_power, aux_power, | | | non_essential_power, essential_power | | 300 | overall_state, prog1_power, day_pv_energy, battery_soc, prog3_charge, | | | prog3_time, prog4_capacity, prog5_capacity, prog1_time, day_grid_import, | | | prog1_charge, day_load_energy, prog6_capacity, use_timer, load_limit, | | | total_battery_charge, prog5_time, day_grid_export, load_frequency, | | | prog3_capacity, prog6_power, day_battery_discharge, prog2_time, | | | battery_low_capacity, total_pv_energy, prog2_capacity, day_battery_charge, | | | priority_load, prog4_charge, battery_voltage, prog5_charge, prog1_capacity, | | | battery_current, inverter_current, total_grid_export, pv1_voltage, prog2_power, | | | prog6_time, prog5_power, prog2_charge, total_grid_import, grid_frequency, | | | total_battery_discharge, grid_voltage, pv1_current, grid_connected, prog4_power, | | | prog6_charge, prog4_time, prog3_power | +-----+----------------------------------------------------------------------------------+
@Leecavturbo nice!
The docs will show you that pv2_power
is another sensor. There is no combined sensor for pv1+pv2 today, but you can build one with mysensors or a template (mysensors is probably more accurate)
If power flow card shows nothing you probably have incorrect entity names. Check these under devices/dev tools- state
@Leecavturbo nice!
The docs will show you that
pv2_power
is another sensor. There is no combined sensor for pv1+pv2 today, but you can build one with mysensors or a template (mysensors is probably more accurate)If power flow card shows nothing you probably have incorrect entity names. Check these under devices/dev tools- state
Thanks any / all help pointers appreciated for a novice 👍
You can use total PV energy sensor for the flow chart . System do the calcul automatically and show only the day prod .
You can use total PV energy sensor for the flow chart . System do the calcul automatically and show only the day prod .
Does that give Pv1+Pv2 power ? Not Kwh
Yes kWh but the HA flow chart only use kWh or you talking about other flow chart?
Le dim. 3 sept. 2023 à 17:23, Leecavturbo @.***> a écrit :
You can use total PV energy sensor for the flow chart . System do the calcul automatically and show only the day prod .
Does that give Pv1+Pv2 power ? Not Kwh
— Reply to this email directly, view it on GitHub https://github.com/kellerza/sunsynk/issues/131#issuecomment-1704333233, or unsubscribe https://github.com/notifications/unsubscribe-auth/AYDJ6M3QMDU5QIIKLKFYWQ3XYSOHLANCNFSM6AAAAAAXGM3XVI . You are receiving this because you commented.Message ID: @.***>
Yes kWh but the HA flow chart only use kWh or you talking about other flow chart? Le dim. 3 sept. 2023 à 17:23, Leecavturbo @.***> a écrit : …
Pv1 power shows the instantaneous KW of that mppt ( string ). pv2 and the combined is what I’m after in kw
You can use total PV energy sensor for the flow chart . System do the calcul automatically and show only the day prod .
Does that give Pv1+Pv2 power ? Not Kwh
SENSORS += MathSensor((186, 187), "PV power sum", WATT, factors=(1, 1))
That works for me, in case you wanna sum of pv1+pv2 in a single sensor
(see this for details, it requires a some hand work)
You can use total PV energy sensor for the flow chart . System do the calcul automatically and show only the day prod .
Does that give Pv1+Pv2 power ? Not Kwh
SENSORS += MathSensor((186, 187), "PV power sum", WATT, factors=(1, 1))
That works for me, in case you wanna sum of pv1+pv2 in a single sensor (see this for details, it requires a some hand work)
Wouldn’t even know where to start and I’ve never seen pv2 (187) as a sensor so suspect more work before your math sensor 👍
I've been wondering if I should not simply add an all
group? (especially for people not reading the docs :wink:)
pv2_power
is now part of the defaults just to show people you can add other sensors. here - do we need to add more defaults?
SENSORS += MathSensor((186, 187), "PV power sum", WATT, factors=(1, 1))
That works for me, in case you wanna sum of pv1+pv2 in a single sensor (see this for details, it requires a some hand work)
Nice solution.
If you use the power flow card you can also visualize two separate sensors and see the total in the UI -
You can use total PV energy sensor for the flow chart . System do the calcul automatically and show only the day prod .
Does that give Pv1+Pv2 power ? Not Kwh
SENSORS += MathSensor((186, 187), "PV power sum", WATT, factors=(1, 1))
That works for me, in case you wanna sum of pv1+pv2 in a single sensor (see this for details, it requires a some hand work)
got samba working and established i can create the .py from windows as notepad save as > in the share/hass-addon . but the code from 'here' link doesn't give your example. just add text below to the code ?
to update pv1 +pv2 sum is now working with SS add-on. Sensor = pv lowercase.
Anyone know what the sensor for UPS load is ? load_2 or output_2 eg ?
Anyone know what the sensor for UPS load is ? load_2 or output_2 eg ?
If you meant backup power output I guess you should read issues about all that sensors ("essentials" is a load on backup output): https://github.com/kellerza/sunsynk/blob/main/src/sunsynk/definitions.py#L91-L104