Skip Kahler
Skip Kahler
This issue arises because until recently the ENDF-6 format did not allow natural element reactions in file 10. Since the CSEWG community has now relaxed this restriction we need to...
With regard to the presence or absence of "e" when writing/reading a real number in scientific notation ... it is a feature of Fortran that ENDF evaluators have taken advantage...
Agreed that my comments on presence or absence of "e" are unrelated to inconsistent delayed neutron group number. I was responding to @paulromano's initial reply to @njchoi where he stated...
natom is not defined in legacy (ENDF/B-III) files but B(1) which is sig(el)*natom is present which is why natom is a user input
e3 was carried forward to e4, e5 and first couple of e6 releases. natom definition appeared when MacFarlane updated the thermal files in e63 (although his report says e62 since...
I believe B(6) is unused ( and therefore set to zero) in e3. That's what's in the e3 h-h2o file but I'd have to check an old manual to be...
Its sample problem #22 from the recent NEA NJOY Workshop. Wim should have the necessary files. Skip On Tue, Nov 13, 2018 at 4:13 PM Jeremy Lloyd Conlin < [email protected]>...
All, The tape number cannot be the same as the main number. This is a long known NJOY restriction. Skip On Fri, Apr 12, 2019, 9:19 AM Wim Haeck wrote:...
Hi Chuck, Still things to be looked into wrt your issue, but I'm getting very different output with "my" NJOY2016.67 version for your 7N14, 24Cr50 and 92U235 jobs, which are...