PrusaMendel icon indicating copy to clipboard operation
PrusaMendel copied to clipboard

In source/metric.scad, m3_nut_diameter is far smaller than the actual diameter of an M3 nut.

Open Lodran opened this issue 13 years ago • 2 comments

This causes an issue with the extruder body, which uses M3 bolts. The nuts at the top of the extruder body are impossible to fit into the nut traps without considerable reworking of the nut traps.

The value given in metric.scad is 5.3mm.

By my measure, it should be 6.28mm.

Lodran avatar Nov 17 '11 05:11 Lodran

The following website lists 5.5mm as the "max" allowed for that part of the nut: http://www.roymech.co.uk/Useful_Tables/Screws/Hex_Screws.htm

pawl avatar Dec 23 '11 12:12 pawl

https://github.com/prusajr/PrusaMendel/pull/57