Jon Billings

Results 15 comments of Jon Billings

Looks like I'm wrong, injector priming respects flood clear in master at least. Pr #289

there's no pwlimit applied even to the primary injectors in table mode. It would be pretty easy to apply pwlimit to both primary and secondary in both modes.

The current logic for non-staged fueling does just limit the DC, I'm pretty sure. Maybe exceeding the injector duty should just be a warning somewhere.

you want ego control to correct to fully warmed up AFRs, before the engine is fully warmed up?why can't you just end WUE at the temp you want it to...

Makes more sense :) I have pid ego control on before end of warmup too, and it just results in it being a bit richer than the target, but stable....