Err:invalid position on csv decode
Hello
Can anybody help me with understanding the following error I receive in my logging. 2021-11-29 13:19:22.378 [update info] received MM cmd: 10030800088025008080c00080 2021-11-29 13:19:22.379 [update error] unable to parse write Allure AC Bedrijfsdata2 from 10030800088025 00 80 80c00080 / : ERR: invalid position I'm looking for the outside temperature which should be located in the 8-9 byte -> 0080
I have a .csv file with the following entry which should match and decode the message according to https://ebus-wiki.org/lib/exe/fetch.php/ebus/spec_prot_7_v1_6_3_d.pdf (§3.4.1) Or am I mistaking?
w,,Bedrijfsdata2,Bedrd2,,,0800,,Field1,,D2B,,,,Field2,,D2B,,,,Field3,,D1B,,,,Field4,,UCH,0x00=WTW_aktiv;0x01=Verwarmingscircuit_activ,,,Field5,,D2B,,,,Field6,,skip,,,,Flied7,,skip,,,
if you set the ZZ to 03 (for the master), then it should work. the default part for the fields is determined from the target. if the target is a master, then the fields are assigned to the master part of the message by default. you could also set the part to "m" for master for every field.
closed due to inactivity