upgrade from 20241027 to latest 20250615 firmware breaks arbitration
i recently upgrade the firmwae to latest after some whle i got greeted with arbitration/connection errors like: [bus error] send to fe: ERR: arbitration lost, retry [bus notice] arbitration won in invalid state receive response [bus notice] arbitration won in invalid state receive response [bus notice] arbitration won in invalid state receive response sometimes the connection would work/ reading values was possible, after some time the ebus connection was lost.
in this times my vaillant arotherm plus was also behaving strangely ( using electic heater/ throwing error about connectio issues)
after reverting back to 20241027 everything works (like it did for ~ 2 Years)
if you tell me where and howto capture usefull debug logs I'll be happy to provide those.
please check again with the current version
i have the same problem / Build: 20251102
ebusd adapter 13:42:07 | Error | handleHostRx: invalid plain 31 13:42:08 | Error | handleHostRx: invalid plain 31
ebusd integratie 2025-11-07 13:43:07.914 [bus error] send to fe: ERR: arbitration lost 2025-11-07 13:43:07.914 [main error] initial scan failed: ERR: arbitration lost
Build: 20251102 ebusd device string: "ens:192.168.178.79:9999" or "mdns:7c2c6761db78" since ebusd 24.1 WiFi station/client: Fritz!BoxSigma, 192.168.178.79, 84% (-58dBm) WiFi access point: inactive Chip ID: 7c2c6761db78, ESP32-C6, rev 1 Hostname: ebus-61db78 Up time: 00:27:51 / 1671 s Free heap: 159004 / 347508 ebusd connected: yes eBUS signal: acquired MQTT connected: yes, topic:
It works for me again. Apparently I made a mistake here: Network adapter address 192.168.178.79:9999
but it must be -> enh:192.168.178.79:9999